My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
818 W CASINO RD 2016-01-01 MF Import
>
Address Records
>
W CASINO RD
>
818
>
818 W CASINO RD 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2017 5:32:43 PM
Creation date
1/25/2017 5:32:05 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
818
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1'�pe li ( ` <br /> CIIOidUI f/II W Garo Rd) <br /> Febuvr I�.]OI I <br /> 5. All partidons shail be dimensioned on the floor plan. <br /> 6. Provide 100 CFM fan vented to the outslde in the kitchen. <br /> 7. Provide minimum 50 CFM exhaust fan in laundry room vented to the outside. <br /> S. A boarding house requires sprinklers. Change all references to"boarding house" <br /> to Single Family Residence (SFR) or provide pians for a sprinkler system <br /> prepared by a Iicensed sprinkler designer. <br /> 9. The wall sectlon shows raised heel trusses. Provide dimens(on of"raised heel" <br /> an,i specify the type of blocking proposed. <br /> 10.Th�: new slab and foundatlon shall be anchored to the existlng foundatlon. Show <br /> connectlon on plans. <br /> 11. �rovide minimum 22"x 30"attic access wftfi minimum 30"dearance over the <br /> access opening. <br /> 12. Provide size and location of attic vendlatlon per R806 Intematlonal Residendal <br /> Code (IRC). <br /> 13. Provide roof framing plan. Specify rooflng material, moisture barrier and <br /> sheathing. <br /> 14. Egress windows shall have a finished sill height of not mo•e tfian 44"above the <br /> floor. <br /> Please prepare a response letter ahowiny where each ibam fn thfs oorrectlon ktte�is <br /> addressed on tfie plan set. <br /> Upon resubmittal of the drawings, your applicatlon will be given prfority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail an� conWin sufficient infortnadon to ensure <br /> that the proposed structure will be constructed In compifance with all adopted codes. <br /> Sincerely, <br /> " �l �1-�� <br /> Jeff He man <br /> Development Technfcian <br /> 425-257-8976 <br /> Email: iheilmanC�ci everett.wa.us <br /> Skcdlion�heilm�N BI IOIA]5(It01 Ra3efelle��ve) ///� <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.