8. Pire Alarm System - An approvcd automatic fire dctection system shail be provided as required by <br /> Ciry Ordinance No. 1902-92, Chapter 1fiJ6, ofthe Gverett Municipal (:ode. <br /> Plans for such system shall be submitted ro the Pire Marshal for review und npproval prior to <br /> installation. Submival shall include cut sheets of ull equipment intended for use. Appropriute trip <br /> tests, witnessed by n Fire Department inspector, shall be performed,nlong with a certificate of <br /> completion, prior to f:nal acceptance of the system. <br /> Fire alarm systcros shall be insmlled according to NFPA 5tondard 72. Installetion of fire slarm <br /> compoucnts, including basic rviring, may not commencc before plans are epproved by the Firc <br /> Department Plan Reviewer. Pirc alarm drawings must be professionally rcndered, in sutTicicnt <br /> detail, and must be internt+lly consistent. Riser diagrums must mntch instnllation plans und load <br /> calculations. Components must be listed and approved for use together. Changes to plans must <br /> include new drawings and culculations and must be approved by the Pire Department Plnn Reviewer <br /> prior to installation. �ire alarm installation is subject to field inspection by u Fire Department <br /> Inspcctor. An approvcd sct of plans and the F3uilding Depnrtment electricnl permit must be present <br /> for any installation inspection. <br /> Fire ulann systems shull bc installed under permit of the City of L'verel I3uilding Department. <br /> Glcclrical inspections and approval nre rcquired prior to calling for acce,.lance tests. �ur permit <br /> information, call (425) 257-8810. <br /> The absence of working phnne lincs for thc alarm system will bc cause for postponing fire <br /> department inspectlon nnd Icsting anJ shall result in denial of occupancy. <br /> 9. A permit is required tiom the Pire Departmcnt for: <br /> I li�h-niled combustible storase. 1'o use nny building or portion thereof as a high-piled storage urea <br /> cxcecding 500 syuare feet. Plans shall be submitted with npplications for such permit,. <br /> 1 Q lii�;h•Pilcd Storaee- 13uilJings containing high-piled combustible storage shall be in uccordunce with <br /> Chapter 23 of Ihe 2003 Intcrnational Pirc Code and NPPA 13. A Fire Department permit is required <br /> tbr high-pilcd storage. <br /> I I. Construclion and Jcmolition uf buildings shall bc in compliancc �vith thc provisions of the 2003 <br /> Intemational I�ire Code, Chapter 14. <br /> 12. Pcnnits arc reyuircd from the �irc Department for removal and installation of underground fucl <br /> tanks. <br /> I z. �lbandoned tanks shall be pumped out and the fuel properly disposed of prior to removal. No product <br /> or rinse wuter may be Jispused of in such a wny that it could enter the storm drains system. <br /> I d. All fire alarm control panels (PACP)and sprinkler valves shnll be in heated rooms or closets with <br /> stanJnrd mnn door acccss. Locutions shnll be approved by the Fire Murshal's Office. <br /> I5. 7Yash Collection - Dumpslers u��er 1.5 cubic ynrds capacity shall be locnted a minimum of 5 feet <br /> Irom thc building �ICC 304.3.3, 200) 8dition]. <br /> � l <br />