Laserfiche WebLink
� <br /> I ' <br /> iferb 13oushey, Director of Operations `I��i�� ��� <br /> Clair Olivers, Asaistant �ngineer �f <br /> �t <br /> October 2, 1978 <br /> PROPOS�D DECLARATION OF NON-SIGNII'I- <br /> CANC� rOR APARTNIENTS IN 1GJ0 BLOCK � � � � �� ���' �� �" <br /> OC' CIi�STNUT � <br /> � <br /> �VAT�R: � <br /> There ia a 2" G.I, mnin on Cheatnut fed by a 2" on 16th from the 12" on Walnut. � <br /> Static preasure in the area is about 100 psi. For fire protection and also to inaure I <br /> adequate domeatic flowa to the apartmenta it will be necessary to extend a E" main � <br /> to serve the site. Thie main could be extended from Walnut but the water system � I <br /> would be gridded better if the main ia extended down Cheatnut from the 6" south oF ' � <br /> 15th. The City would participate in thie main extenalon if funds are available. A I <br /> hydrant would have to be placed at 16th and Chestnut. <br /> S�W�R & DRAINAGE: <br /> jThere is an 8" main on Cheatnut which should have adequate capacity for sanitary I <br /> flows, Since thia line flows to the trunk on 16th which flows one bloek to the inter- <br /> ceptor, it would seem unnecessary to require on-site detention at this eite. <br /> STR��TS: <br /> Necessary improvementa tu Chestnut Street ehould be required adjacent to thie site. I <br /> � i <br /> cc: Celia Strong i <br />, <br /> � <br />� <br />