Laserfiche WebLink
, , <br /> . . <br /> Puecic wo��rs <br /> December 12, 2011 <br /> Bustard Custom Construction Inc. <br /> PO Box 1243 <br /> Marysville WA 98270 <br /> Subject; Project: Bustard Custom Homes Inc. <br /> Job Address: 5105 Chinook Dr <br /> Plan Check No: Cilli-011 <br /> Dear Mr. Bustard: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2009 International Building Codc,) (2009 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br /> City of Everett, unless stated othcrwise. <br /> In order for the processing of your applicatlon to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> rnrrections requested. <br /> 1. The elevation views shall refled adual site conditions, Usc survey data in your <br /> possession to accuretely depid the structure as it will be when built on the site. <br /> 2. Provide laterel analysis for wind and seismic ioading based on revised drewings <br /> (see item 111 above). <br /> 3. Show height calculations on elevation view(s). Provide elevation of garage Floor, <br /> main floor and basement Floor. Show on elevation and/or section drewing <br /> specific to this strudurc. <br /> 4. Based on the site plan submitted, the elevation of the ground at thc sliding glass <br /> door is approximately seven feet below the basement slab-on-gradc. Provide <br /> plans for any deck strudure on the back (downhill) side of the house. <br /> 5. Provide details/sections for tall crawl space walls. <br /> 6. Provide lateral analysis and grevity calculations for e�Rerior deck based on <br /> revised elevations. <br /> 7. Provide consUudion details for exterior deck and guard on deck. <br /> 8. Provide architecturai drawings, notes, sections and/or details for construction of <br /> the residence, including but not limited to: <br /> a. Insulation at below grede walls; specify framing, spacing and fire <br /> b�ocking. <br /> b. Label windows "safety glass" in hazardous locations as defined in sedion <br /> R308 IRC. <br /> c. Show steps from house into garege or provide detail. <br /> y�.ao�+�rwm.au i i�oi i(si os o���oo��n� <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-BB00 • Fax (425) 257-8882 �(L <br />