My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:41:42 AM
Creation date
1/26/2017 10:21:44 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Notes
PROVIDENCE EVERETT MEDICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` 3 <br /> ii n > <br /> = � � <br /> :3 F � <br /> !� E � < <br /> E <br /> e�c u a z° <br /> C 5 � Complete plans and specifications for the firo alarm system installation or <br /> modificadon shall be submined for review and approval prior to system installation. <br /> P�ans and specificadons shall inciude, but not be limited to, a floor plan; locadon of <br /> aIl alarm-initiating and alarm-signaling devices; alazm-control and trouble-signaling <br /> equipment; annunciation; power connection; battery calculations;conductor type and <br /> sizes; voltage drop calculations;name, address, and phone number of the agency <br /> receiving off-premises transr.ussion of alarm; and the manufacturer, model numbers <br /> and listing information for all equipment,devices, and materials. Incomolete nlans <br /> and specifications will be retumed without review. Plans and specifications may be <br /> submitted sepazately from consttuctiun documents during the consWction of the <br /> project. For small renovation projecls in which devices are onty to be relocated, a <br /> plan that shows the relocation of devices can be submitted for review in lieu of the <br /> above requirements. Seclion 10013, Unifocm Fite Code <br /> Approved Ol/OAl03. <br /> C 6 O Provide handwash sink for ICRU, and ICRU3. <br /> Approved 11/15/02 -Sinks provided in hall way and rooms. <br /> C 7 O Swing doors from toilets outward. WAC 246-320-525(2)(e)(iv) <br /> A 7.1 Nct Approved i 1/25/02- Define who will have access to Toilet C335. <br /> Approved Ol/13/03 - Revised Drawing A2.3C label Toilet C335 as a Statf Toilet <br /> C g p Provide cross-corridor opposing-swing doors at south end of corridor B386. <br /> Approved 1L25/02- Existing door to remain, and additional opposing-s�ving <br /> Door R346 added. <br /> C 9 � Provide medical gas zone valves for critical patient care areas. <br /> Approved l l/21/02-Ba�ed on drewings received 11I01102,which show locations <br /> of required zone valves. <br /> C ]0 0 Provide separate room for toilet in wing 3C. <br /> Approved 1?!03/02-Based on drawings received 11/Ol/02,which show separate <br /> toilets in each room. <br /> C 11 � Provide reduced pressure backflow pteventer for dialysis machine connection. <br /> Provide a detail of ciialysis boxes. <br /> Approved 11/15/02-Approved tixed air gap provided on dialysis box. <br /> C 12 0 Provide 20-minute doors for nurse servers serving wing 4A. <br /> Approved 11/25/02- Wing 4A not part of this project. <br /> Pagc 4 of 1 I Plan Review Comments for Project#6345 <br /> Review Kcy: A=Archiiccl F=Fire&Life Safe�y 5=Snnitarinn M=Mtthanical!Electrical C=Conference Note <br /> rr <br />
The URL can be used to link to this page
Your browser does not support the video tag.