My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:41:42 AM
Creation date
1/26/2017 10:21:44 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Notes
PROVIDENCE EVERETT MEDICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> • .� <br /> � � i <br /> 9 E <br /> Y �i ' g <br /> E <br /> � u' < z <br /> C2 18 � Provide a reduced pressure backflow assembly on thc water service to the pop <br /> machine. WAC 246-320-540(4)(a),WAC 246-215-120(4), and WAC 246-290-490 <br /> Approved 11/15/02-See M6.1 riser 315. <br /> C2 l9 � An exemption will be required to locate a water closet within the ICU patient room. <br /> FVAC 246-320-065, and WAC 246-320-725(2)(c) <br /> Approved Y1/IS/02-Water closefs are located in toilets. <br /> C2 20 � Enclose the nourishment room. WAC 246-320-535(6) <br /> Approved l V15/02- Nourishment funcHon is in side rooms C215 and B341. <br /> C2 21 � Provide tamperproof receptacles in Waiting room P007 in accordance with <br /> WAC 246-320-405(9)(e)(ii). <br /> Approved 1ll2L02-Based on drawings received 11/Ol/02,which show locstlons <br /> of required tamperproof receptacles. <br /> C2 22 � Ice machines shall have appropriate backflow protection. Air-cooled ice machines <br /> shall have an air sepazation or air-gap on the drain line. Water-cooled ice machines <br /> shall have a reduced pressure backflow assembly on the potable water lines and an <br /> air gap separation on both drain lines. WAC 246-290-490(2)(b) i <br /> Approved 11/15/02-See M6.1. <br /> C2 24 � Provide fire smoke/d�mpers at penetrations of the l-hour occupancy sepazation that <br /> defines the boundaries of the suite. WAC 246-320-405 (6), Section 713 (0, Unifortn <br /> Building Code, and Section 713.11, Unifortn Building Code.The wall shall be <br /> constructed per Section 3023(4), Uniform Building Cale with all openings <br /> protected by a fire assembly having a one-hour rating fire protection rating. <br /> Approved 11/21/02-Based on�lrawings ceceived I1/Ol/02,which show <br /> fire/smoke dampers at all required locations. <br /> C2 25 � Suites shall not exit through adjoining suite. Section 1007.5.9, Uniform Building <br /> Code amendments <br /> Approved 11/25/02-Norlh half of Wing 3C is a suite tl�at exits to rated <br /> corridors at two locations. South half of Wing 3C is N��T a suite, but has ell <br /> patient rooms opening to a rated corridor. <br /> C2 26 0 Provide a detail of the dialysis box. <br /> Approved 11/15/02 -See M6.2 <br /> Pagc 7 0( I I Plan Review Comments For Project#6345 <br /> Review Key: A=Archi�cci F=Fire&Life Safe�y S=Sanitarian M=Mechanical/8leclrical C=Conferrna NWe <br /> �1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.