Laserfiche WebLink
� - <br /> PUBL/C I�t/O/�J�Lri <br /> February 26, 1997 <br /> Mr. Brad Liger <br /> 2206 Colby Avenue <br /> Everett WA 98201 <br /> SUBJECT: 2202 Colby, Everett, WA <br /> Dear Mr. Liger: <br /> In order to legalize the duplex at the above mentioned address the following buiiding <br /> code issues must be comple[ed. <br /> �� Smoke detectors are required in all sleeping rooms and in the azea ]eading to each <br /> sleeping room. <br /> • Each sleeping room on the second floor unit must have one window with an <br /> openable area of 5.7 square feet minimum, openable heigh[ of 24 inches minimum, <br /> openable width of 20 inches minimum and a sill height of 44 inches maximum. <br /> The sill height may be achieved by a permanent fixture such as a book shelf. <br /> • Handrail on the upper floor stairways in compliance with the building code section <br /> 1006.9. <br /> A building permit is required to perform this work. This permit can be obtained at this <br /> office. The electrical permi[ may also be obtained when the building permit is issued. <br /> If you have any questions, please call me at 259-88t0. <br /> Since�ly, <br /> � �� �iGc��� <br /> Tim Tyler <br /> Building Official <br /> 7T:jd:lig<r <br /> CITY OF EVER[TT• 3200 Cedar Street • Everelt, WA 98201 • (206) 257-8800 • Fax (206) 257-fl856 <br />