My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2212 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2212
>
2212 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 1:18:51 AM
Creation date
1/27/2017 1:18:21 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2212
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � � <br /> ��/��/� ���/�i`'.� <br /> May 3, 2013 <br /> leff Davis <br /> Davis Construction, Inc. <br /> 18 W. Marilyn Ave. <br /> Everett, WA 98204 <br /> RE: O�vner: Greenlee, Virginia M. <br /> Job Address: 2Z12 & 2Z10 Colby Ave. <br /> Plan Check No: 61304-033 & 61304-032 <br /> Dear Mr. Davis: <br /> In response to your application for a construccion permit, your plans have been examined and <br /> you are advised that revisions may be necessary before a permit can be issued. Please review <br /> and respond to the comments below. These comments address building issues only. Additional <br /> revisions, or additions, may be r?quired by other departments (such as Utilities, Planning or <br /> Fire). AII references refer to the 2009 International Building Code (IBC), the 2009 International <br /> Fire Code (IFC), the 2009 Intemational Mechanical Code (IMC), and the 2009 Washington State <br /> Energy Code (WSEC), as amended by the State of Washing[on and adopted by the Ciry of <br /> Everett. The current IBC referenced standard for accessible design is the �003 "Accessible and <br /> Usable Buildings and Facilities" (1CC/ANSI A117.1). Federel ADA regulations and standards may <br /> be more mstrictive. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction <br /> documents reflecting the corrections requested. <br /> 1. The riser heights shall be 7 inches maximum. Stai� tread depths shall be 11 inches <br /> minimum measured horizontally between the vertical planes of the foremost projecfion <br /> of adjacent treads and at a right angle to the tread's Icading edge. IE3C 1009A.2 <br /> 2. The submilted drawings indicate a combination guard and I�andrail on the sides of the <br /> stainvay. IBC 1013 requires a 42" high guard on both sides of [he stairway. IBC <br /> 1009.12 requires a handrail on both sides of the stainvay. IBC 1012.2 requires the <br /> handrails to be 34 to 38 inches high. In other words, both sides need to have a 47" <br /> high guard with the handrails altached to the insides. The handrails must comply with <br /> grasp-ability requirements of IBC 1012.3. The guards must comply with structural <br /> requirements of IBC chapter 16. Please provide guard detailing. <br /> 3. The handrails are required to eMend and continue to slope for the depth of one tread <br /> (11 inches) past the bottom riser. At lhe top, handrails are required to extend <br /> horizontally at least 12 inches beyond the top riser. IBC 1012.6. <br /> If you I�ave any questions, please call me at 425-257-7264. <br /> CITY OF E\/ERETT • 3200 Cedar Street • Everelt, WA98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> s�.ic�m.m,�,�a.,�.tiniai.,�uw.:>>x oi±cu: <br />
The URL can be used to link to this page
Your browser does not support the video tag.