My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2526 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2526
>
2526 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 2:51:06 AM
Creation date
1/27/2017 2:50:19 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2526
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- �. <br /> _ ^ <br /> �.. <br /> .�- <br /> �: <br /> WendelURuth Walker <br /> Plan Check NB-41609 <br /> August 26, 1993 <br /> Page 2 of 3 <br /> 9. Exit doors shall be openable from the inside without the use of a key, speciai <br /> knowledge or effort. Section 3304(c). Panic hazdware is required on the rear <br /> e�cit and signage of the main entrance must comply with Section 3317(d) <br /> Excepdon 1. <br /> 10. Every required exit doonvay shall be of a size to permit the installadon of a <br /> 3'0" x 6'8" door. A minimnm clear width of 32 ir.ches must be provided. <br /> Sec6on 3304(�. <br /> 11. A floor or landing not more than one inch [�/z"j below the threshold is <br /> required on each side of an ezit door. 3ection 3304(i). <br /> 12. Corridors must have a minimum width of 44 inches. Section 3305(b). <br /> 13. Exits shall be illuminated to comply with Section 3313. <br /> 14. Provide exit signs in conformance with Section 3314. <br /> 15. Walls and ceilings of corridors are required to be of 1-Hour fue-resistive <br /> construcdon. Section 3305(g). An azchitectural section through the wrridor <br /> is necessary to determine how this is accomplished. <br /> 16. Interior openings into corridors are required to be protected as set forth in <br /> Section 3305(h). Self-closing or automatic closing twenty-minute rated door <br /> assemblies properly gasket should be provided. Other openings aze limited to <br /> 3/4-Hour rated fized glazing and shall not exceed 25% of the azea of the <br /> common wall, <br /> 17. All doorways leading to accessible rooms shall have an unobstructed clear <br /> width of not less than 32 inches. Section 3106(j). <br /> 18. Accessible doors shall have maneuvering clearances per Section 3106(j)3. I <br /> 19. A clear cucular unqbstructed floor space 60 inches in diameter within the <br /> toilet room is required. Doors may encroach into this space by not more tha�, <br /> 12 inches. Section 3106(k)2. <br /> 20. Provide gnb bars per Section 3106(k)Sc and 3106(k)11. <br /> 21. A clear space 30 inches wide, 29 inches high and 17 inches in depth shall be <br /> provided under each lavator�. Section 3106(k)7c. A clear floor space not ]ess <br /> than 30 inches wide a�id 48 mches deep is required in fron', of]avatories and <br /> sinks. Section 3106(k)7a. <br /> � <br /> i �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.