PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per Cfty Slandard#601. <br /> 5. Connect side sewer per Cily Slandard#'s 607, 602, 604. <br /> 6. Connect all rooftop downspouts lo the side sewer. <br /> 7. Connecl rooflop downspouts to lhe drainage system provided for th�s lot. <br /> 8. Rooitop runoR must be discharged to a roof downspoul infiltration system per Gty of Everett Stonn <br /> Manual 3-2.G2. The approximate size trench is 3.5'�vide, 2'deep and 25'lonc�. See attachment for <br /> moro dotails. <br /> 9. Tho contractor must meet with ihe Public Works Inspeclor to discuss potential drainage routing prior to <br /> beginninc� tha pro)ect. <br /> 10. Install erosicn conlrol measures as delermined by Ilie Public Works inspector, sucli as silt fence, slrsv; <br /> bales, swales, or eroslon blankets. <br /> 11. Instali erosion conlrol measures per City of Everetl 3landards for small parcels <br /> 12. Removo erosion conlrol measures upon completion of the project prior te tinal approval of the permit. <br /> 13. All excavaled material from foundation, sidewalk and driveways �hall be hauled to an approved, <br /> perm�tted sitc. No v;aslin� of material is allowed on lhis buildinc�lol. <br /> ��7� No dirt, inud, rocE:s or debris lo be U'2cked onlo road�vay. ' <br /> 15. No building materials lo be stacked on sidewalks and sidewalks lo be kept clean and open for <br /> pedestrlan lravel. <br /> 1G Adjusl walet meler box 1"above sidewalk c�radc. <br /> 17. Remove and replace curb, c�uller and sidewalk as per Ciry of E-veretl Standard Plan#'s 305A 8 30G on <br /> Ihis proposal's fronta�e as dirccted by the Pubtic Works Inspeclor(i.r., all unused driveways and any <br /> broken or dainac�ed area musl be replaced). <br /> 1 B. Install a Type I wncrcle driveway per Cily of Everelt Standard#307. <br /> 19. f�ave driveway irom the front property lino oul to the street paving. <br /> 20. Conlacl Uie Waler District(or connecting provisions for this building's a�ater and <br /> sewer servicos. <br /> �21. A catch basln as per Cily StUndard Plan�402 with a c�as trap per Standard Pian#410 is required for the <br /> parking aroa. <br /> 22. If a sewer pump system is to be installed, tho pressuro line must discharge into a private manhole, the� <br /> gravily ilow across the publfc right-of-way. <br /> 23, A sprinkler sysfem is required for tliis building in compliance willi the requiremenls of NFDA Standards <br /> 13D. <br /> PWCommenls <br /> �y <br />