Laserfiche WebLink
• 5en! vin e-mail � <br /> � PUBL/C it/OR/C5 y/s/ r�- � <br /> -- � <br /> September 5, 2014 <br /> Mr. Kyoung Kimlee <br /> 9825 18`" Ave W G2 <br /> Everett, WA 98204 ' <br /> Owner. CORPUS TIMOTHY & PERRIGO DONNA <br /> Project: Change of occupancy from Bar to Retail <br /> ]ob Address; 2608 Colby Ave • <br /> Plan Check No: 61409-007 <br /> RE: Corrections Letter <br /> Dear Mr. Kimlee, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that this is an incomplete submittai. Please review and respond to the comments <br /> below. In order for the processing of your application to continue, it will be necessary to <br /> provide the euilding Division with two complete ncw sets of construction documents reFlecting <br /> the corrections requested. Please indude a response letter which indicates how the corrections <br /> �vere resolved. <br /> �General <br /> 1. The drawings are not to scale. Although the drawing is very much improved, it is still <br /> not accurate. Please reference the previously e-mailed plan drawings to create a new <br /> plan to show existing walls and doors last permitted. Any walls or doors not on that <br /> permit would be considered as new, to meet current code, even if built. <br /> 2. Please schedule a site visit with me to review the existing basement and discuss the use <br /> of it under this new permit. There are several notes regarding the basement access on <br /> the previously issued plans which should be taken into consideration on this new permit. <br /> All codes cited refer to the 2012 International Building Code (IBC), the 2012 Infernational Fre <br /> Code (IFC), the 2012 International Mechanical Code (IMC), and the 2012 Washington State <br /> Energy Code (WSEC), as amended by the State of Washington and adopted by the Ciry of <br /> Everett. The curre�t IBC referenced standard for accessible design is the 2009 "Accessible and <br /> Usable E3uildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards may be <br /> more restrictive. These comments address building issues only. Addilional revisions or additions <br /> may be required by other departments (such as Utilities, Traffic, Planning or Fire). All required <br /> submiltals must be of sufficient detail and information to ensure that the proposed strucWre <br /> will be constructed in compliance with all adopted codes. <br /> i erely, <br /> Meg Hale RA <br /> Plan Revie rchitect, 425-257-8813 <br />