My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2707 COLBY AVE ANDERSON HUNTER 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2707
>
ANDERSON HUNTER
>
2707 COLBY AVE ANDERSON HUNTER 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 3:43:31 AM
Creation date
1/27/2017 3:43:13 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2707
Tenant Name
ANDERSON HUNTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> n,corts�iuci�[oN nocut�rrrs <br /> Three (3) compiete sets with site plans. Minimum scale: 1/8" = 1'0". <br /> � A.Floor pian with compiete dimensions (indicate endre building showing all exit <br /> doors, stairs, corridors, etc.); .' <br /> � Tt. Buiiding section with vertical dimensions indicating location of tenant <br /> improvement, other tenants and building construction; <br /> �FF/4��f/T�GTU�At- <br /> _C� C.Wall sections indicating prop�sed construction and assembly rating as required <br /> for accupancy separation, area separaGon or building conswction; <br /> � D.Scair or ramp ian� (1/4" = 1'0" minimum scale) and sections; <br /> 5E�' �Ptz�IrecTvrz� <br /> _j_C , E. Toilet toom plans (1/4" � 1'0" minimum scale) and interior elevaGons (indicate <br /> wall and floor finishea, fizture dimensions, handicap accessories (if required) and <br /> toilet accessories; ' <br /> �_ F. Door schedule (indieate fcame and door rating, type of lock or latch and signege <br /> if required); <br /> _� G.Lighting pian and energy budget calculations (indicate wattage of all fixtures, <br /> include exterior building mounted lighting if added or revised); <br /> � H.Energy calculations (any exterior wall or roof of ezisting buildings must be <br /> insulated when the frammg caviry is exposed when remodeling. Caviry must be <br /> insulated to the maximum depth possible or to the depth indicated by energy <br /> calculations); <br /> �' I. Stnict�ral drawings and calculations (oniy required if altering existing structure <br /> or adding new load-bearing strUcture); <br /> ,� J. Architect's or engineer's stamp. (All projects of 4,000 square feet or moro than <br /> 4 dwelling units requiro the plans to be prepared by an architect or engineer <br /> currently licensed to practice in the State of Washington); <br /> � K.Copies of an permits/a rovais issued by the Planning Department; <br /> ,s�c Ar��r��r�r�c. <br /> ��" L. Cuireirt assessed value of the building from the Snohomish Counry Assessor <br /> (required only if the building is not equipped with a complete automatic fire <br /> suppression system). <br /> � � ��„�t<�niro» <br /> .,, . <br /> ^ �/ � <br /> ,�;,r <br /> _ , ,` � <br /> � t'.,- . . . . <br /> � y �� . »y .��. <br /> �� ' r �} N 1 '4 Y A� <br /> � dt a- � 1-r � FYa i ��, <br /> ....._. . J��'.�.. . � vm.;$s`�s'+'.AS`v'Y1'i.-.Y."�et-'F�. �.� . "'v r.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.