My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2707 COLBY AVE BASE FILE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2707
>
BASE FILE
>
2707 COLBY AVE BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:56:06 PM
Creation date
1/27/2017 5:01:30 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2707
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 13, 1993 <br />Mr. John W. Augenstein <br />Abacus Consultants, P.S. <br />i 401 Second Avenue South Suite 201 <br />Seattle, Washington 98104 <br />PROJECT: Everett Mutual Tower <br />SUBJECT: Building Life Safety Systems Design (Response to your letter of May 18, <br />1993 received September 10, 1993). <br />Dear John: <br />I have reviewed your May 18, 1993 letter to AFM Warren Barns and have the <br />following comments. <br />The City of Everett has adopted the 1991 Uniform Building Code as amended by the <br />Slate of Washington. This code will be the basis of my comments and any deviation <br />from the requirements of this code must be approved as described in Section 105 or <br />Section 106. <br />Item 1: Stairway Pressurization <br />The section that you have referenced as the code basis (Section 3310(g)5) requires <br />smoke proof enclosure construction with vestibules at all enclosure openings. The <br />plans prepared by NBBJ do not reflect this requirement. <br />However Exception I Section 3310(b) allows the construction as illustrated by NBBJ if <br />the shaft is pressurized as indicated in the exception. <br />Item 2: Smoke Control <br />Your proposed smoke control system appears to be "normal" for high rise buildings but <br />must be approved as allowed by Section 1807(g)3. <br />F—mal approval will be by the Building Official but we must also have approval from <br />the Fire Marshall prior to our approval. I am in contact with AFM Brad Olson and <br />will respond when we have reached a decision. <br />Item 3: Sprinkler System Secondary Water Source <br />The proposed second tie-in into the water main does not constitute a "... Secondary On <br />Site Supply of Water...". <br />We understand that this issue may be appealed under the provisions of Section 204 as <br />discussed in our meeting of September 10, 1993. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 - (206) 259-8800 • Fax (206) 259-3882 & <br />
The URL can be used to link to this page
Your browser does not support the video tag.