My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2707 COLBY AVE TULLYS COFFEE 2018-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2707
>
TULLYS COFFEE
>
2707 COLBY AVE TULLYS COFFEE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2018 11:53:50 AM
Creation date
1/27/2017 5:25:30 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2707
Tenant Name
TULLYS COFFEE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1994 Washin on State Nonresidential Ener Code Com liance Fortn <br /> � � • . <br /> 1iW NM��hpbn SbM1 NonmtlMlal EMryY Co01 Complhnu FOrtn� Jun.1GW <br /> Prescri �IVC$ 8CC5 Oceupancy ❑Warehouses,ctonpe areot a aircrall stonpe hanpen ❑ Olher <br /> Qualification Checklist Liphtinp Fidures: ❑ Check here if at Ieast 95%ol futures In the space meet ai�lour eriterir. <br /> Note:It occupanry trye fs"Othef'entl fulure <br /> ensror ia cnttked,ll�e numDer M fu2urea m 1.Fldurec are Iluorestent,non-lensed,wlth only onc or Mro lampa,and <br /> Ihe space ic not hmilee by COEe Cleary <br /> �neicete these apaces on plam. Itnot 2.Lamps are T•5,T-6,T•B or PL,and 3.Lamps are 5•W Watts,end <br /> Qualdied,tlo LPA Caicuiations. 4.8allasts are elxtronle ballasts <br /> Table 15-1 Unit Lighting Power Allowance(LPA)for Interior Lighting <br /> LPA� LPA' <br /> - Use' (Wlh°) Use' x <br /> (W/R <br /> Palntln ,welCin ,ca ent ,machine sho s 2.J poiice end 1 re stations' 11 <br /> Barber sho s,bea sho s 2 Atda �triums t <br /> Hotalb�n vaVconlerencs/azhibrtionhsA" 2 Assemb s aces' audkonums nesia� theaters 1 <br /> Leboretones 2 Praess plants 1 <br /> Aircrok re sir hm ars 1.5 Rnhunnlshen� 1 <br /> , Cefeteries festfoodesteblishmenb� 1.5 ReteiU'0 1 <br /> Fectorin,worksho e,hendlin erees 1.5 Ret�il B10 Rehil bmkin 1.5 <br /> G�s stetions eWo re air sho s' 1.5 Locker endlor shower fecilities 0.8 <br /> Ins171Wians 1.5 Warehouses�� stora eareas 0.5 <br /> Libraries' 1.5 Aircnflstora ehen an 0.4 <br /> . Nursin homes 1,5 Perkin era ea "'•�k�•^���� <br /> � W`�otesek stores(pellel nck sh¢Ivinp) 7.5 <br /> Mall concourses 1.4 Plani Submined Por eommon Areu Onl � <br /> Schools 6ullcin s,s�hool classrooms,tle nre centen 1.35 Common erea,corntlors,bbbles exce t mellconcours¢ O.B <br /> Laundrks 1.3 Toiletfacilitiesendwashrooms O.B <br /> ORice buildinps,olficelatlministretive ereas in facilPoes of <br /> otMr us�typea(inciudinp but not IimI1W to schools, 1,2 <br /> honpMals,instKutians,museums,banks,ohurchas�°°�" <br /> Footnotes for Table 15-1 <br /> I. In enses in ufiich a use i:not mentioned specifically,the UnuPmrerAlloH�auce shell M1e determined bythe building ofliciel.This <br /> detcrmination shall bc based upon ihc most companblc usc spaified ie ihc teblc.Sce Scction 1512 for excmpt arees. <br /> 2. The��ans per squnre foot mey be increaaed,by h�o percem per loot of ceiling height e6o��e nvenry feet,unless specifically directed <br /> athcnvise by subaequent fomnotes. <br /> 3. u'etts per squerc foot of room maq be incrcased by hvo percent per foot of cciling height ebove iweh•e fect. <br /> 4. For ell othtt speces,such es seeting end common erees use ihe Unu Ligln PoH�erAlloN•ance fin essemblq. <br /> 5. Wtlta per squere foot of room mag be increesed by turo percent per foot of ceiling height abo�•e nine ket. <br /> 6. Inciudcs pump arce undc�cenopy. <br /> 7. In ascs in ufiich e lighting plen is suhmiticd for mly e portion of a�oor,a L'nil Lighting Poutr Nimcancc of I.35 mey be uscd for <br /> useble o�ce floor aree and 0.80�wtls pa square faot shal I be used for Ihe common ercas,���hich mey include eie��e�or spece,lobbr eres <br /> end rest rooms.Comhiotl'erees,es herein defined do not include mell concourses. ' <br /> 8. For thc fire engine room.thc Vnit Lighting Pourr Alio��ance is I.0 aaus per squere foo�. <br /> 9. Fur indoor sport tournament couns aflh edjacent spectetor seating,ihe L�nit Lighting Powtt Allouance for the court nrea is 2.6 uatis ptt <br /> squ�re foot. <br /> ]0. For both Reteil A and Rcteil D,lig�it for Gcc•stenJing displey,building shot��cese illuminetion end dispiny��indow illumine�ion instelled <br /> ��i�hin h�ro fat of thc window erc cscmpt. <br /> Rcieil A elloi�s e lMit Lighting Poacr Allo��rncc of I.0�vatis per squem fcwt.Cciling mounted edjusteble tungaten hslogen�nd HID <br /> mttchandise dispin•illuminerics ere exempt. <br /> Releil�ello�cs e Unit Ligh�ing Po�ver Allo��nnce o!1.5��alls per squere foot,including ell cciling ntounted merchnndise Jispley <br /> luminaries. <br /> 11. ProvideA�het a Ooor plen.indiwting reck louiion anJ height,is wbmiued,ihe 3quere foolege fa e�varchouse may be defineA,for <br /> computing�he interior Unit Lighting Po��rr Allo��ance,as�he Owr erce not coecred by racka plus the�•atial fece eree(eccess side oniy) <br /> otthencks.The height ello�vance defined in fa�tnote 2 epplies onlyto the tloor eree not coverod by recks. <br />
The URL can be used to link to this page
Your browser does not support the video tag.