Laserfiche WebLink
C'Vef`.'.iE � <br /> ^'� t <br /> ' ;f . "_ .. ....; 6t <br /> . `` ._r�'/ } <br /> ,4_ F <br /> August 9� 1976 � ihe.Evergrecn <br /> . c�rr oF <br /> eve r�tt <br /> CITT HGIL � P39•Blu <br /> , ' . � • [V[IICiT. WA6111N6TOM <br /> Bryant, Butteriield and Frets, Architects � , .�, •a:^� <br /> 717 Medical Dental BLSSZdYIIg ' INS�CCTION DVAPTNENT <br /> Everett. :4a. 982�1 '' ����'� <br /> � <br /> Reference: Alteration to exterior of Henning Building <br /> Colby and California . <br /> Plan Check No. 76-382 <br /> Gentlemen: <br /> The Plans for the above referenced project have been reviewed <br /> � and the following corrE�ctions are required to comply with the <br /> Uniform Building Code. <br /> 1. The maximum height or thickness of a marquee shall <br /> not exceed nine (9) feet. Section 4505 (d) . <br /> . 2, A marquee shall be constructed of non-combustible <br /> material. Section 4505 (e) . <br /> 3. ' All portions of any a�aning shall be at leasl: eight <br /> feet above any public walkway. <br /> 4. Structural column at corner shall be one hour protected. <br /> Table 17-A. <br /> 5. New one-hour wall on south side shall be of non- <br /> � combustible material. Section 2003 (a) . <br /> Yours truly " <br /> Jamie G. Johnson <br /> - Building Official <br /> gy � (�;� c••-�«. ,._. <br /> Ren Callahan <br /> Plans Checker <br /> JGS:ItC:eb : <br /> _. <br />