My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2811 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
2811
>
2811 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 6:54:44 AM
Creation date
1/27/2017 6:53:12 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2811
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. iza9t <br /> - Page 2 <br /> 6. All control, druin, test and alarm valves on the automatic sprinkler <br /> system must be provideo with identification signs of s[a�tlard design or <br /> tneir equivalent. <br /> a. second floor system <br /> 7. The electrical extension cord(s) must be removed. If additional outlets <br /> are �ecessary, they must be i�stalled in accordance �itn the Electrical <br /> Code. <br /> a. second floor--southrrest office desk <br /> 8. A serious problem rith the exiting exists on the second, third, and <br /> fourth floors. <br /> The Uniform Building Code defines a�i exit--'A continuous and unobstructed <br /> means of e9ress to a public way, a��d shall include intervening doors, <br /> doorways, corridors, exterior exit balconies, ramps, skairreys, <br /> smoke�proof enclosures, horizontel exits, exit passage rays, exit courts, <br /> and yards' (Sec. 3301(b)). <br /> 1'he Uniform Building Code requires that--'the second story shall be <br /> provided with not less then tr+o exits Mhen the occupant load is ten or <br /> more' (Sec. 3303(a)) end 'occupants on floors above the second story and <br /> in basertients shall have access to not less th�an two separate exits from <br /> the floor or basement' (Sec. 3303(a)). <br /> The occupants of this area of the building do not have access to exits es <br /> reWired !n the co0e. The second mea�s of egress gces out o� the roof of <br /> the building next door. The problem is further compiicated by leck of <br /> adequate exit signs. Neither is there any provision �or emergency <br /> 1lghting in this area .here there is ra netu:al light. Any fire SnciOent <br /> .hich involved the exit steirray or eny access to the stairray rould <br /> certeinly put the occupants in �eoperdy of serious in3ury or worse. <br /> The code states that buildings rhich are 'not provided •ith adequate <br /> egress are, ' 'for the purpose of this section, unsafe' (Sec. 203 UBC <br /> 1985). Such unsafe cenditions are to be sbated by repair or <br /> rehabilitation. Failure to provide suct� repair or rehabilitetion cauld <br /> result in an order to vacate the offendinq areas. <br /> Therefore: <br /> Under pecmit of the City of Everett 8uilding Department, provide an '� <br /> approved means of egress from the second, third, and fourth floors. <br /> 9. Provide approved illuminateU exit sign(s) to indicate location of rear <br /> exit. <br /> a. main floor <br />