_ ( <br /> ENG/NEE/i/NG/PUBL/C SE/�Y/LE5 OEPARTiNENT <br /> Novcmber 2,2007 <br /> Mr. Adam Clark, Archilcct <br /> Gary Parkinson Architccts <br /> 2812 Colby Avenue <br /> Gvcrett,WA 98201 <br /> Projech Do��7itow» k3anya (bascmenQ <br /> Job Address: 2S 14 Colby A��cnuc <br /> Plan Revicw No: 130705-047 <br /> Dcar Adan, <br /> In response to your revision to Qic approvcd perniit plans, yaur plans },ave becn examincd and <br /> you arc adviscd thal a pennit cannot be issucd until the following issucs ar:resolved. In order fur <br /> the proccssing your application to continue, it will be necessary to providc the 13uilding Division <br /> wilh two sets of documenls rc0ecting Aic corrcclions rcquestcd. <br /> Constructlon <br /> 1. 'Chc permit and drawings issued on G/18/07 should either Uc revised to indicate a B <br /> occupancy with a maximmn of 49 occupants in thc basement (instead of an A-3 <br /> occupancy with 128 occupants), per IIIC Section 303.1; or, if additional occupants arc <br /> anticipated (ovcr 49 total in the entirr. bascment at any onc time), thc cxiting on thc <br /> drawings should be rcvised to providc 1/3 thc largest diagonal of the tenant space <br /> scparation bctwcen thc Iwo exit doors, per IBC 1015.2.1, and the specific occupancy and <br /> o�cupancy lypc for cach room should Uc calculated on thc drawings, per IBC Scetions <br /> 303.1, 1004.3 and 1004.9. <br /> 2. 'I'he pennit issued on G/18/07 and drawings should be rcvised to indicate Construction <br /> Typc V-A* wilh *sprinkler exception in licu of rated assembly. <br /> 3. 7'he total occupancy load in thc basemcnt should be identified on thc drawings and postcd <br /> in the spacc with a maximum occupancy load,per IBC Section 10043. <br /> 4. 7'he usc of thc range hood identified in thc ncw kitchcn arca shoitld be idcntified on thc <br /> drawings. If it is kilchcn to distriUutc catcred food and is uscd for warming only, a Type <br /> I }Iood would not bc requircd. I3owc��cr, if thc foods bcing prcpared producc grcasc or <br /> sleam, then a Typc I liood, Type I Hood duct and make-up air duct should be shown on ' <br /> thc nrchitectural drawings per IMC Scction SOG3 and 507.2. <br /> 5. Clmdes Jolmstonc, Ciry of L'vcrclt]ndustrial Prctrcatment, should be contacted to discuss <br /> bneasc handling rcquircments. ]Ic can be reached dircctty at 425-257-8224. <br /> G. The architcctural drawings should show how the materials, mechanical design and <br /> basement plenum sections will be built for moisture conhol and air leakage for the poois, I <br /> showers and stcam rooms,per\VSLC Sections 1313 and 1314. <br /> � <br /> CITY OF EVERETT' � 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 �I2 <br /> s�num.�+wM�wo�os.a�=eu coror n��do� I <br />