Laserfiche WebLink
- ,., <br /> �, . <br /> PUBL/C N/O/�K5 <br /> , ,�, <br /> DecemUer 1, 1994 ' <br /> b4i. Chuck Cgden <br /> Skotdal Enterprises <br /> �810 C�>lby, Suite 20l <br /> 1"sverett WA 98201 <br /> PROJE�:T: 2825 Colby, 2nd Floor T.l. <br /> SUBIECT: Preliminary Review (ncr your request) <br /> Dear Chuck: <br /> I The revisions I receivecl l(/30/94 look good r.xcept for the following: <br /> 1. The exit adjacent to the lunch room must be separatecl by a one hour ratecl wall <br /> and door 1/17 must be 20 min. rat�d. <br /> 2. Door numbers 8, 17, 27, 28 and 31 m!ist have an eighteen inch maneuvering <br /> dearance on the swing side at the strike jamb. <br /> i 3. Door nuanbers 17, 28, 31 and 31 must be 20 min. rated and installed in one <br /> hour rated walls. <br />� 4. Directional exit signs must be provideci at door numUer 17 and 31. <br />� $. Wall construction and bracing details must be provided. <br /> I <br /> t I 6. A lighting plan and lighting power allowance calculations must be provided. <br /> I The plans must Ue stamped by an architect licensecl in the State of Washingron. <br /> Please provide the aUove intormalion on two sets of completed plans with a completed <br /> pennit application and we will proccss so inspections can proceed. <br /> Sincerely, <br /> , �, �� �/ . <br /> E ' Y S. CC'ALL <br /> Assoc. Eng./Bldg. <br /> 1Mycd:ogdcn 1<� <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (206) 259-�802 • Fax (206) 259-8859 � <br />