Laserfiche WebLink
i <br /> � <br /> 1.0 INTRODUCTION <br /> Southem Environmental Sciences, Inc. conducted emissions testing of the Industrial Equipment <br /> 8� Engineering Company Model IE43-ET, Ener-Tok cremetor on Novembc�r 6, 1997. The unit is <br /> located at 5500 Williams Drive, Punta Gorda, Florida. Testing was conducted for the <br /> particulates, carbon monoxide, and visible emissions. Oxygen (02) concentrations were <br /> measured in order to correct results to 7°� Oz. <br /> 2.0 SUMMARY OF RESULTS <br /> The equipment•was found to be in compliance with all applicab{e emission limiting standards. <br /> Results of the particulate and carbon monoxi�ie testing are summarized in Tabte 1. <br /> The aversge measured particulate emission concentration was 0.017 grains per dry standard <br /> cubic foot (corrected to 7°� Oz). <br /> The average measured carbon monoxide emission concentration was 21.8 parts per million by <br /> volume (corrected to 7°r6 0,). <br /> A visible emissions evaluation was conducted over a 60 minute period. The maximum three <br /> minute average opacity was 0 percent. <br /> No objectionable odor was detecled during the stack test by the testing personnel. <br /> � <br /> 1 �/ <br />