Laserfiche WebLink
Pr/BL/L /�t/ORKri <br /> September 15, 1999 <br /> William C. Brockway, AIA <br /> 3216 Wetmore Ave. � <br /> Everett, WA 98201 <br /> SUBJECT: Solie Funeral Homc <br /> 2201 Colby Avenue <br /> Dear Mr. Brockway: <br /> Although the mechanical portions of the project will not be reviewed until the mechanical <br /> permit is applied for, the fullowinK item was noticed which will impact the new <br /> crematory: <br /> • Section 814.6.1 (UMC) states that metal chimneys of commercial and industrial-type <br /> incinerators shall extend at least 3' above roofs measured from the highest point at <br /> which the metal chimney passes through the roof. Further, the chimncy shall cxtend <br /> at Icast 10' higher tha�i any portion of a building within 25'. <br /> The chimney could be raised to any given height in order to comply with the cicarances <br /> of the existing building. However, as the parking lot adjacent to the funeral homc <br /> (South) is a separate piece of property, we must ensure that no building could ever be <br /> constructed within 25' of the chimney. To accomplish this, a "no-build" easement <br /> (boundary line adjustment, or other approved means) will he required to be in effect for <br /> thc issuance of the mechanical perniit. The ease.ment should be recorded through the <br /> Snohomish Counry Auditors Oftice. <br /> If you have any questions, plcase give me a call at (d25)258-8810. <br /> Sincercly, <br /> �� �� <br /> ny R. Lee <br /> Associale Lngineer <br /> �tjcso�ics <br /> CITY OF EVERETT• 3200 Cedar Street • Everett,WA 98201 •(425) 257•8800• Fax(425) 257-8856 <br />