My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3424 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
3424
>
3424 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 11:23:08 AM
Creation date
1/27/2017 11:22:45 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3424
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br /> . _ I �� <br /> C,ode Compliance <br /> INSPECTION REPORT <br /> ent Housin Ins ector/Code Compliance Oflicer <br /> . Marian D P <br /> FROM• � S <br /> . `� <br /> DATE: July 16, 1999 ���� <br /> SUBJ: 3424 Colby Ave.,Everett,WA <br /> CASE: 1308-99 . <br /> At the request of the tenant at this address, an inspection of this house was conducted <br /> today. During the inspection, several deficiencies were noted which make it reasonable <br /> to believe that the building is substandazd and or dangerous pursuant to the Housing Code <br /> and Dangerous Building Code as adopted by the City of Everett. <br /> Listed below are some of the deficiencies noted during the inspection: <br /> 1. There is a lack of heat in the house. <br /> 2. The mortaz in the fireplace box is deteriorated and missing in some areas <br /> to such an extent,the bricks of the fire box are dislodging and falling out. <br /> 3. There is a structural stress on the south side of the building which is <br /> causing the cantilevered floor of the upstairs bed to slope down causing <br /> cracks in the wall and floor of the bedroom and ceiling and wall of the <br /> room below. The wallboard on this wall, which is an exterior wall, has <br /> been removed exposing the stud framing and exterior siding to the interior <br /> of the room. <br /> 4. The water drain of the bathtub in the up�'^irs baUvoom leaks causing the <br /> tloor to rot and the ceiling below to sag. <br /> 5. The clotlies dryer does not vent to the exterior of the building. <br /> G. There is no handraiUguazdrail on the basement steps. <br /> 7. There is no handrail on the stainvay ro the second floor. <br /> � <br /> r � <br />
The URL can be used to link to this page
Your browser does not support the video tag.