My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3601 COLBY AVE 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
3601
>
3601 COLBY AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2022 10:57:08 AM
Creation date
1/27/2017 12:11:09 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3601
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. �>..� al""77 <br /> 4n <br /> �#.�'.• ."`c'�+ <br /> ...r,r:�?. <br /> i �.,' <br /> P1an Check No. B-36499 <br /> June 25, 1993 <br /> Page Two of Two <br /> ✓10. Enclosed usable space under stairs must be protected on the enclosed side as required fur 1-HR <br /> fire-resistive construction. Section 3306(1). See also Section 3309(�. <br /> v�ll. Ail doorways ]eyding to accessible rooms shall have an unobstructed c_��,._�d�h of not less than <br /> 32 inches. 5ection 3106(j)• This item applies to door No. 5. <br /> �'�k <br /> 12. A clear circulu unobstructed floor space 60 inches in diameter within the toilet room is required. <br /> 6� Doors may encroach into this space by not more than 12 inches. Section 3106(k)2. <br /> � �}� 13. Alarm systems shall include both audible and visible a]arms and shall be located per Section <br /> �� 3105(d)9. <br /> �4. One in every eight accessible par]dng stalls, but not less than o�e par]c�ng Stall� Shali �omply with <br /> the van parlung space requirements in Section 3107(b), <br /> ti'(Z�j 15. Due to the limited scope of the structural en ineerin <br /> entical nature of structural connections in ex�ting s�sm��callymtrotfilttedrbu 1din�s,dstructutraj <br /> observation in accordance with Sec6on 307 is required. <br /> The structural observation must be performed by Johnson Coastline Association. <br /> �4�> 16. Special inspecfion for welding and bolts installed in concrete or C.n4.U. is required per Section <br /> 306. <br /> l�l�• Please provide details of the connections of the steel reinforced 6 x 8 floor beams to the existing 'I <br /> C.M.U. walls. <br /> In order for the processing of your application to continue, it will be necessary to provide the Building <br /> Division with two complete new sets of drawings reflecdng the conections requested. <br /> Upon resubmittal of the drawings, your application will be given priorit}� and plan review <br /> recommence. <br /> All required submitt<�ls shall be of sufficient detail and contain sufficient information to ensure that the <br /> proposed structure wi]1 be constructed in compliance with all adopted codes. <br /> Sincerel , <br /> � <br /> � cF <br /> Associate Engineer/Building <br /> IM:cg/plenck(S <br /> _ _ _ �..��i� <br />
The URL can be used to link to this page
Your browser does not support the video tag.