Laserfiche WebLink
.. �>..� al""77 <br /> 4n <br /> �#.�'.• ."`c'�+ <br /> ...r,r:�?. <br /> i �.,' <br /> P1an Check No. B-36499 <br /> June 25, 1993 <br /> Page Two of Two <br /> ✓10. Enclosed usable space under stairs must be protected on the enclosed side as required fur 1-HR <br /> fire-resistive construction. Section 3306(1). See also Section 3309(�. <br /> v�ll. Ail doorways ]eyding to accessible rooms shall have an unobstructed c_��,._�d�h of not less than <br /> 32 inches. 5ection 3106(j)• This item applies to door No. 5. <br /> �'�k <br /> 12. A clear circulu unobstructed floor space 60 inches in diameter within the toilet room is required. <br /> 6� Doors may encroach into this space by not more than 12 inches. Section 3106(k)2. <br /> � �}� 13. Alarm systems shall include both audible and visible a]arms and shall be located per Section <br /> �� 3105(d)9. <br /> �4. One in every eight accessible par]dng stalls, but not less than o�e par]c�ng Stall� Shali �omply with <br /> the van parlung space requirements in Section 3107(b), <br /> ti'(Z�j 15. Due to the limited scope of the structural en ineerin <br /> entical nature of structural connections in ex�ting s�sm��callymtrotfilttedrbu 1din�s,dstructutraj <br /> observation in accordance with Sec6on 307 is required. <br /> The structural observation must be performed by Johnson Coastline Association. <br /> �4�> 16. Special inspecfion for welding and bolts installed in concrete or C.n4.U. is required per Section <br /> 306. <br /> l�l�• Please provide details of the connections of the steel reinforced 6 x 8 floor beams to the existing 'I <br /> C.M.U. walls. <br /> In order for the processing of your application to continue, it will be necessary to provide the Building <br /> Division with two complete new sets of drawings reflecdng the conections requested. <br /> Upon resubmittal of the drawings, your application will be given priorit}� and plan review <br /> recommence. <br /> All required submitt<�ls shall be of sufficient detail and contain sufficient information to ensure that the <br /> proposed structure wi]1 be constructed in compliance with all adopted codes. <br /> Sincerel , <br /> � <br /> � cF <br /> Associate Engineer/Building <br /> IM:cg/plenck(S <br /> _ _ _ �..��i� <br />