My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3624 COLBY AVE 2016-01-01 MF Import
>
Address Records
>
COLBY AVE
>
3624
>
3624 COLBY AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2017 12:27:57 PM
Creation date
1/27/2017 12:26:43 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3624
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ , � � <br /> Occupancy <br /> J1. The apartments should be shown as an R-I Occupancy on the cover sheet. Section <br /> 310.1 <br /> � 2. All load bearing members (exterior and interior walls, beams and posts) supporting <br /> the one-hour occupancy separation between the B and R-1 Occupancies should be <br /> shown as minimum one-hour rated assemblies. Listings should be provided with <br /> the construction details. Section 302.2 <br /> �/3. The following comments apply ro the one-hour occupancy separation on the second <br /> floor per Section 302: <br /> Va) The occupancy separation wall between the office/storage and the aparunent <br /> should be shown on the plans. The full separadon wall should continue to the <br /> under-side of the roof sheathing (vs. the draft stop specified). <br /> /G) The walls separating the stairs from the dwelling units should be shown as <br /> occupancy separation walls. The doors ttvough the walls should be shown as <br /> inimum 60-minute rated assemblies. <br /> �y c) The glazing shou[d be removed from the occupancy separation in the stair wall, <br /> � or comply with UBC Standard 7-1 for walls - a cut sheet should be provided for <br /> the ceramic glazing if used. <br /> � As shown, the den in appt. �/1 does not comply with habitable room requirements <br /> as follows: <br /> a) The floor area should be shown with a minimum of 70 sf. Section 310.6.2 <br /> b) The clear width in both directions should be a minimum of 7 feet. Section <br /> 310.6.3 <br /> c) Compliance with natural light and ventilation requirements per 5ection 1203 <br /> should be clarified. <br /> � Any walls separating the dwelling units from the corridor or office space and the <br /> floor/ceiling assembly should be shown with a minimum 50 STC pistings should be <br /> provided). Appendix Section 1208 <br /> � The locations of the smoke detectors should be shown on the plans. They should <br /> be hardwired with battery backup. Section 310.9 <br /> �'7 Any nonflammable medical gas supply cylinders located inside the building should <br /> be separated from the rest of the building in accerdance with Section �310 — details <br /> should be provided. <br /> �8� Windows in Bedroom �12, Apt �12, and Bedroom 111, Apt N3 are missing from the <br /> floor plans. <br /> \ 9. The door inro the shower room from Bedroom Nl, Apt �/2 is missing from Ihe floor <br /> plan. <br /> / `I <br />
The URL can be used to link to this page
Your browser does not support the video tag.