Laserfiche WebLink
. <br /> . ,��:.�.�:::..,,�- , . <br /> � �� � <br /> .. �'. � D � � � � l'J �D M O�S��NN <br /> � <br /> � ,�!.11! � 5 2000 nM��r <br /> � ---+- JOEL O.NIEMI <br /> DYKEMAN �+ GARYO"IEAfN <br /> CITY OF EVERETT �ws�,�RH <br /> � � �����i�.�--��� �9fR112 $BNICES �O�SM.iRED1VAV <br /> - � - PAULD.7URMAV. <br /> � TIM TWIEfMEYER <br /> May 31, 2000 <br /> Mr. Tony Lee, Associa�e Engincer RE:Tufarolo Dental Clinic <br /> City of Everett Pcrmit Center 3614 Colby Avenue <br /> 3200 Cedar Street Plan Check#B0004-028 <br /> Evcrett, Washington 98201 <br /> Dca;Mr. Lce, <br /> Attached are two set of drawings with the revisions and/or clarifications requesled in your letter <br /> dated May 16,2000. The individual items are discussed bclow in the same order as your <br /> wmments. <br /> General: <br /> 1. As allowed by the UBC Section 504.6,we have added a 2-hour arca separa�ion wall at Grid <br /> 3.2. This dicides thc building into two buildings so ihal it will not requirc an automalic <br /> sprinkler syslem. initially we understood this was no�an issue because the D occupancy was <br /> Iess than 6,000 SF and Ihe R occupancy did not require a sprinkler system for the number of <br /> our proposed residential units. Thc currcnt sprinklcr ordinance is out of da�e with Ihe UBC <br /> and is no� wrilten as dcarly as it should be in order to be rcasonably understood. Our project <br /> is on a iighl time-line and wc do not have thc luxury of lime to appcal this decision. Thc sizc <br /> of our building is well below the size threshold of�hc UBC for requiring an automalic <br /> sprinkler system. <br /> 2. An approved monilored fire alartn syslem will be provided as rcyuired by the ordinance. The <br /> electrical,securily and fire alarm systems are designed by Ihe General Conlraclor's forces. <br /> They will obtain all required pertni�s. <br /> 3. Thc two windows at Ihe souih property line havc hollow metal frames and will be rated for 45 I <br /> minutes. This has been added to�he schedule,drawing A5.1. <br /> Occupancy: <br /> 1. The apartments have been nofed as an R-] occupancy on the�ille drawing A1.0. <br /> 2. The framing and columns supporting the 1-hour occupancy separation between Ihe B and R-1 <br /> occupancies have been noled as 1-hour conslruclior,. Details and notes have been added�o <br /> Ihe drawings .42.] for�he columns and A4 for the floor and ceilings. <br /> 3. Occupancy Separa�ion: i <br /> a) Thc separation wall betwecn the officc/storagc and apartment extends lo the underside of I <br /> the roof shcathing as •_, •ired see drawing A2.3. <br /> b) The wall at the apa� � .nt en�ry s�air�t1 is noted as 1 hour on shect A2.1 B <br /> c) The glazing in the stair wall will be in a hollow mctal frame and have a 1-hour fire rating. <br /> Attached is a manufacture's cut shee� on the "pyrostop" fire protec�ion glass. <br /> 4. The apartment#1 area previously noted as the den has been combined wi�h the living room <br /> and the doors have been removed so it is an alcove off the living room. <br /> 5. Thc walls separating the dwelling uni�s from the corridor or adjacent office have a minimum <br /> STC rating of 50 as noted on Ihc drawing A2.1B. <br /> 6. The smoke de�ec�ors required in the sleeping rooms and main living space are noted on the <br /> re0ected cciling/lighting pian, A2.2. <br /> �Y � <br /> . , . . _ .. . ._ �.- � ..';rll. lM1'Av5iC�I.7'���, • PHQNF4'52SJ-31L7 PrA?` 1'i'_;6i i-1JA'.__i. 3�v�n- .:, r�. <br />