PUBLIC WORKS PERMIT COMMENTS <br />4. Connect side sewer per Ciry Standard #601. <br />5. Connect side sewer per City Sta�dard #'s 601, 6D2, 604. <br />6. Connect all rooftop downspouts lo lhe side sewer. <br />7. Connecl rooftop dovrnspouts to the drainage system provided for this loi. <br />8. Rooftop runoff must be discharged to a roof downspout infiltretion system per City of Everett Storm <br />Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />11. <br />12. <br />13. <br />14 <br />15. <br />1G. <br />17. <br />18. <br />19. <br />The contraclor musl meet wilh the Public Works Inspector to discuss polential drainage rouling prior lo <br />beginning the projecl. <br />Install erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br />bales, swales, or erosion blankels. <br />Install erosion conirol measures per City of Everetl Standards !or small parcels <br />Remove erosion contro� measures upon completion oF the project prior to final approvai of the permit. <br />All excavaied material from foundation, sidewalk and driveways shall be hauled to an approved, <br />permilted site. No wasling of material is allowed on Ihis building lot. <br />No dirt, mud, rocks or debris Ic be �racked onto roadway. <br />No buildinn materials to be slacked on sidewalks ar�d sidewalks to be kepl clean and open for <br />pedestrian travel. <br />Adjusl waler meter box 1" above sidewalk grade. <br />Remove and replace curb, �utter and sidewalk as per City of Everetl Standard Plan #'s 305A & 306 on <br />this proposal's (ronlage as directed by the Public Works Inspector (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />Inslall a Type I wncrete driveway per Cily oi Everetl Standard #307. <br />Pave driveway from the front property line out to the street paving. <br />20. Contact the _ <br />sewer services. <br />21. <br />22. <br />23. <br />Waler District for connecting provisions for !his building's water and <br />A catch basin as per City Siandard Plan i1402 with a gas lrap per Standard Plan !W 10 is required for the <br />parking area. <br />If a sewer pump system is to be inslalled, the pressure line must discharge inlo a private manhole, then <br />gravily flow across the public righbof-way. <br />A sprinkler system is required for this �uilding in cornpliance with lhe requiremenls of NFDA Slandards <br />13D. <br />FVJCom�:ienis <br />