Laserfiche WebLink
. 1997 Washir m Slale Nonresidential Ener Code Com lia• Form <br /> . _ . <br /> 1E9]Wasningmn Stale Nonresidonlial Energy COEe Compliance Forms Fvs�EEnion-June.1998 <br /> ProectAddress �a�e 8/11/2008 <br /> � �ollar Treo <br /> n <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the <br /> Washinyton Slate Nonresidential Energy Code. <br /> Applicabiliry Code Localion Building Department <br /> (yes,no,n.a.) Section Component Information Required on Plans Notes <br /> HVAC REQUIREMENTS (Sections 1401-1424) <br /> 1411 Equipment peAormance <br /> yes 1417.4 Pkg.elec.hlg.&clg. List heat pumps on schedule <br /> yes 1411.1 Minimum eKciency Equipment schedule with type,capacity,effciency <br /> 1412 HVAC controls <br /> yes 1412.1 Temperature zones Indicate localions on plans <br /> .a. 1472.2 Dezdband control Indicate 5 degree deadband minimum <br /> .a. 1412.3 Humidily control Indicate humidistat <br /> yes 1412.4 Automalic setback Indicate lhermostat with night setback antl 7 diff.day types <br /> �yes 1412.4.1 Dampers Indicate damper location and automalic conlrols <br /> .a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule <br /> yes 1472.6 Combustion htg. Indicate modulating or staged conirol <br /> yes 7412.7 Balancing Indicale balancing fealures on plans <br /> yes 1422 Thermoslat inlerlock Indicale lhermoslat interlock on plans <br /> yes 1423 Economizers Equipment schedule <br /> 1473 Aireconomizers <br /> yes 1413.1 Operalion Indicale 100%capabilily on schedule <br /> yas 1413.2 Control Indicale controls able lo evaluale outside air <br /> yas 1413.3 Integrated operation Indicate capability(or partial cooling <br /> 1414 Ducting syslems <br /> yes 1414.1 Duct sealing Indicate sealing necessary <br /> yes 1414.2 Duct insula:ion Indicate R-value of insulation on ducl <br /> yes 1415.1 Piping insulalion Indicate R•value of insulation on piping <br /> yes 1424 Separale air sys. Indicate separate systems on plans <br /> Mech.Sum. Form Completed and altached. Equipmenl schedule with types, <br /> inpuVoulput,effciency,c(m,hp,economizer <br /> SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) <br /> 7440 Service waler htg. <br /> yes 7441 Elec.water heater Indicate R-70 insulalion under tank <br /> � yes 1442 Shut-ofl controls Indicate automatic shut-oH <br /> 1450 Heated pools <br /> 1452 (reserved) <br /> i.a. 1453 Pool heater contmis Indicate switch ard 65 degree wntrol <br /> .a. 7454 Pool covers Indicate vapor retardant cover <br /> .a. 1454 Pools 90+dearees Indicate R-12 pool cover <br /> no is circ e or any question, provi e exp anation: <br /> �. `�) <br />