/ <br /> 8. Please locate the cmployee lockers and coat racks sho�•m nn A2 in floor p1an. <br /> bilerior Regttiremen(s <br /> 9. Support of the office cciling to undersidc of structure should be indicatcd on thc drawings, includ:ng the <br /> distance to the undersidc of stnicture, such ihat the partition walls will resist a horizontal load of Spsf.. <br /> 1'hc cop of the officc cciling should not be used for storagc, unlcss additional structure is added and <br /> ilaor aceess is added to the drawings. <br /> 10. Inslallation of the new cciling sl�ould be�s per attached Norlhwest Technical Inslitule bulletin, to <br /> include stabilization for seismic rcquircments:md 2 inch angle requiremenls at edge of ceiling. <br /> Deferred iYfechn��icnl Submitta! <br /> 1 L Mcchanical ver.tilation systr,ms should be submitted in a separate mechanical permit applicalion. <br /> Dejerred Sib�i�age Sub»rirrnl <br /> 12. l;xterior signagc and modifications to pole signs should Ue sobmitte�. in a separate sign permit <br /> application. <br /> Upon submission of hvo insert sets uf revised drawings reflecting the corrections requcsted,your application <br /> will be processed. ApplicaUle codes includc thc 200G Intumational Building Code (I}3C),the 200G International <br /> Firc Code (IPC),the 200G Intemational Mechanical Code(IMC), ihe 2006\�✓ashington State Gnergy Code <br /> (WSrC),the 200G Washington State Ventilation and Indoor Air Quality Code(V1AQ), and the 2003 Accessible <br /> and UsaUle Buildings and �acililies Al 17.1-2003 (ICGANSI). All codcs refcrenccd, as adopted by the City of <br /> �veretl, sl�ould include current revisions by the State of�Vashington. These comments address building issues <br /> only. Revisions or additimis may be requircd Uy other dcp�rtmeNs(such as Utilities, Planning ar�ire). <br /> Si�v rel , • <br /> I' <br /> :I <br /> i� <br /> Mcg Haley, N, .AI2I3 <br /> 1'lans�:<atnincr <br /> i <br /> �� I <br /> � <br />