Laserfiche WebLink
2004 Washin con State Nonresidential Ener ' Code Com lianc,. . orm <br /> • • <br /> • <br /> y0W Was�i��on SL ta NonresiGen4al Energy CW e Compiwnce Porms RersnO lAay 2W 5 <br /> P�ojectAddress q9y0 e.argzeen way �a�e 3/23/2007 <br /> Complete the following for all design A&B squirrel�cage,T-frame induction permanently wired polyphas� <br /> For Building Depanment Use <br /> motors from 1 hp to 200 hp having synchronous speeds o13600,1800 or 7200 rpm(unless one ot Ihe <br /> ezceptions below applies). <br /> Motor Min.Nom. <br /> No.or Type Synch. Fullload <br /> Lowlion HP (open/closed) Descriplion of AUPliration or Use Speed Efliciency <br /> RTU-1 3 Exevp[!on 3 <br /> R1v-= 3 Exception ] <br /> RT[I-] 3 F�cception 2 ' <br /> R'CU-4 3 Ezception 3 <br /> RN-5 ' 1- 1�Y Exceptron 3 <br /> RTO-6 1- l�Z Exceptlon 2 <br /> RTU-] 1- lI2 ExcaPtian 2 <br /> Minimum Nominal Full-Load Efficienc <br /> O en Molors Closed Matas Exceptions: <br /> Synchmrous 1. Motors in systems designed to use mora <br /> S eod IRPM) 3.6�0 1.800 1.200 3,600 7.800 1200 Ihan one speed of a multi-speed motor. <br /> HP Efliciencv °61 Efticienr.v %) 2. Motorsalreadyincludedintheefliciency <br /> 7.p 82.5 80.0 755 02.5 80.0 requirements for HVAC equipment(Tables 14-7 <br /> 1.5 82.5 84.0 84.0 82.5 &7.0 85.5 or <br /> 2.0 84.0 84.0 85.5 84.0 &1.0 B6b �4-2)• <br /> 3.0 84.0 BG.S B6.5 85.5 87.5 87.5 3. Motors that are an iategral part(i.e.eol easi <br /> 5.0 85.5 87.5 87.5 07.5 87.5 87.5 removed and replaced of specialized pmcess <br /> Z5 87.5 BB.S 88.5 88.5 89.5 89.5 equipmenl(i.e.equipment which requires a <br /> 10 08.5 89.5 902 89.5 09.5 89.5 special motor,such as an explosion-proof motor). <br /> 15 89.5 91.0 902 902 97.0 902 4. Molors integral lo a listed piece of equipmer <br /> 20 90.2 91.0 91.0 902 91.0 902 lor which no quali(ying motor has been approved <br /> 25 91.0 91] 917 97.0 92A 917 (i.e.i(the only U.l.listing for the equipmenl is <br /> 30 97.0 92.4 92 4 91.0 924 91.7 with a less•etficient molor and Ihere is no energ� <br /> q0 917 93.0 93.0 91.7 93.0 93.0 eKcient mo�or option). <br /> 50 924 93.0 93.0 92.4 93.0 93.0 <br /> fi0 93.0 93.G 93.6 93.0 93.6 93.6 For motors claiming an ezceplion,list motor and <br /> 75 93.0 94.1 93.6 93.0 94.1 93 6 nole which exception applies. <br /> 100 93.0 94.7 94.1 93.6 94.5 94.1 <br /> �25 93.6 94b 94.1 9d.5 94.5 94.1 <br /> 150 93.6 95.� 94.5 94.5 95.0 95.0 <br /> 200 94.5 95.0 94.5 95.0 �J5.0 95.G <br /> � ����� <br />