My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5929 EVERGREEN WAY BASE FILE 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
5929
>
BASE FILE
>
5929 EVERGREEN WAY BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2017 10:01:56 PM
Creation date
2/9/2017 10:00:40 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5929
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
491
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br /> r <br /> 2 foot intervals. Iriigation systems must be provided in all landscaped areas per <br /> Section 35.130 of the Zoning Code. A 2 year maintenance assurance device <br /> must be provided for the landscaping per Section 35.130B of the Zoning Code. <br /> 20. Based upon 19,600 square feet of Type V-1, sprinklered construction, the fire flow <br /> requirement is 1,875 GPM. <br /> 21. A fire hydrant is required within 200 driving feet, but not closer than 50 feet, of every <br /> st�ucture. An additional hydrant must be installed. The location of the hydrant must be <br /> approved by the Fire Marshal. Locations shown on the revised site plan are acceptable. <br /> 22. A sprinkler system complying with EMC Chapter 16.76 must be provided. <br /> Plans fo•any such system m�ist be submitted to the Building DepaKment and the <br /> Ever�tt Fire Department for examination and approval. Such plans must include p!ans <br /> for the underground mains that will supply the sprinkler system. <br /> As of January, 1991, sprinkler system permits are issued by the Building Department. <br /> Plan review fees are assessed by the Building Department. No fee is assessed by the <br /> Fire Department. <br /> Above ground sprinkler piping must be hydrostatically tested as established in NFPA <br /> Standard 13. Underground piping must be hydrostatically tested and flushed as <br /> established in NFPS Standard 24 for private fire mains. All such tests must be <br /> witnessed by 3 Fire Department inspector. Call 259-8710 to make an appointment for <br /> inspection. <br /> Contractors' materials and test certificates must be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call 257-8120 for more information. <br /> 23. The building(s) must have an automatic fire detection system installed in accordance <br /> with NFPA standard 72, and EMC Chapter 16.76. <br /> 24. Portable Fire Protection -A portable fire extinpuisher with a minimum U.L. rating of 2- <br /> A:10-B:C shall be provided within 75 feet of travel on all floors of aach building during <br /> construction and prior to occupancy. <br /> 25. Fire lanes must be provided as required in Everett Municipal Code 46.44. Fire lanes <br /> must be identified by red curbs with white stenciling stating "NO PARKING - FIRE <br /> LANE" and vertical signs stating "NO PARKING - FIRE I.HNE -TOW AWAY ZONE." <br /> Location must be approved by the Fire Marshal. <br /> 26. The premises must be clearly identified by address at the stree�t entry. Each building <br /> must be clearly identified so as to be visible and legible from the access road. Each <br /> suite must be cleariy identified so as to 6e visible and legible from the access road. <br /> 27. When access to or wlthin a structure or an area is unduly difficult because of secured <br /> openings or where immediate access is necessary for life saving or fire-fi�hting <br /> purposes, the Fire Department may recommend or raquire a key box to be installed in <br /> an accessible location. A rapid entry system may also be desirable in ord�r to avoid <br /> unnecessary damage while making entry to any building during an emergency situation. <br /> � 2930 Wetmore, Suite 100, Everett, WA 98201 'S (206) 259-8731, Fax (206) 259-8742 <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.