Laserfiche WebLink
J O H N H. F A R R E N S, J R., • A R C H I T E C T <br />fl726 202nd STREET S.W., EDib'.ONDS, VJASHINGTON 98020 •(206) 774-1965 <br />ADDENDUM N0. 1 <br />ADDITION TO AL�S AUTO SUPF�,Y <br />6500 �reregreeu Way <br />Everett, Sdashington <br />John H. Farrens, Jr., Archi;tect <br />1. The area within tne exterior walls is 13,300 sq, feet. <br />See definition of floor area Sec. 407. <br />2, Proyide 2 N0.3 bars in top oP new masonry wall. <br />3. Move personnel door in east wall so the south jamh is 1�6" <br />north of column line 5. <br />4. The door� shown as 1,1/2 hour fire doors shall have U.L. <br />labeled assemblies iscluding jamUs and fiardware� and shall <br />have automatic closers. <br />5. Toilet rooms shall have 3�0° wide doors. <br />6. (a) There shall be a minimwn of 32" clear in front of toilet stools, <br />(h) Install grab bars on side and at rear of toilet stool. <br />(c) A clear space 26" in width� 24" in height and 12" in depth <br />shall be proVided under lavatories. Projection of bowls <br />and piping excepted. <br />