Laserfiche WebLink
�7 �f e J"Pc�� � rCc� 'iG <br />��Trashracks s3��e�-ld be installed on the existing swale ouL-fa.11 <br />` and inlet pipes, if trashracks weren't installed p�:eviously. <br />The ground elevation will be raised in the a'rea above the <br />swale, particularly along the portion of the swale running <br />eest-west. If possible, the side slopca of the swale should <br />/ not be disturbed during cor.struction. Grading on the site <br />� must not result in the swale's side slope exceeding 3:1 <br />(H:V), unless a retaining structure is used to provide a <br />vertical drop. Adequate grading information and/or cross <br />sections must be provided to show the final side slope of <br />the swale. <br />Miscellaneous: <br />The City has recently identified a general problem with <br />�restaurant dumpsters. If possible, this area needs to be <br />covered and isolated hydrologically through the use of <br />berms. Drainage from the area should be routed to the <br />sanitary sewer through an oil/watei- separator or grease <br />trap. Other options, such as water-tight dumpsters, may be <br />allowable. <br />✓ Additional comments are written directly on the plans. <br />