Laserfiche WebLink
C <br />DYKEMAN 8. OGDEN, ARCHITECTS P.S. <br />3216 WETMORE AVE.. EVERETT, WASHINGTON 98201 (206( 259-3161 <br />November 19, 1979 <br />Johnson -Carruthers <br />300-120th N.E., Suite 230, Bldg. 3 <br />Bellevue, Washington 98005 <br />Attention: Tom Ellsworth <br />Gentlemen: <br />DAVID W. DYKEMAN, A.I.A. <br />CHARLES B. OGDEN, A.I.A. <br />ROBERT G. ALDRIDGE <br />GARRY V. QUINTON <br />B. CRAIG THOMPSON <br />7�'- o / E"'- , <br />kl�z� <br />RE: CASCADE SHOPPING CENTER <br />SAFEWAY #517 <br />This letter is for clarification of attic draft stop locations <br />mentioned in Item No. 1 of City of Evorett Building Department plan <br />correction sheet dated 10/23/79. <br />Attic draft stops as detailed on Sheet n5, Section 95 and <br />Sheet #7, Section 95 are required between Grid S3 and Grid S8 on <br />Grids SC, SD, SE, SE.9 and SF. <br />The partition between Grid SD $ SE on Grid S3 and between <br />Grid SE and beyond Grid SF shall be considered part of the system <br />of draft stops, providing a continuous attic, separation. G.W.B. <br />must be continuous through space above ceilings. <br />The mezzanine Scull on Grid S3.9 between SB E SC shall also be <br />a draft stop with closure provided to the roof structure and <br />extending from the mezzanine wall to Grid SC. <br />Very truly yours, <br />Robert G. Aldridge <br />RGA/ j g <br />cc: Alan Roodhouse <br />Everett Building Dept., Ken Callahan,' II <br />CITY ui, (;VER=TT <br />Inspection Dept. <br />to E M B E R S 0 F T H E A M E R I C A N I N S T I T U T E 0 F A R C H I T E C T 5 <br />