Laserfiche WebLink
:NG/NEER/NG / PUBE/C SE/�Y/CES OEPA?TAlENT <br />February 11, 2005 <br />Ms. Michelle llouglas <br />Ancor Inc. <br />831 Jamcs Slrcet, 2"� Ploor <br />Syracuse, NY 13203 <br />Projecl: Sbarro <br />JoU Address: �verett Mall, 1402 SL Everctt bfall Way <br />Plan Rcvicw No: MQ8C1r008 and K0802-003 <br />llear Ms. Douglas, <br />In response to your application for a construction pemiits, your plans liave Ueen examined and <br />you are advised that a perniil cannot Ue issued until the following issucs are resolvcd. In ordcr for <br />the processing your application to continuc, it will Ue nccessary to provide thc 13uilding Division <br />with two sets of insert drawings re(Iccting the corrections mqucsted. <br />NIOS42-OQS Construction <br />]. 7'ype I and 1'ypc ]I Iloods should be identified on the exhausl fan schedule in lieu of <br />"Kitchen t lood" and "Piz�a llood", respectively. Our jurisdiction has acccpted thc <br />suUmitted mnnufxturer's recommendation for the usc of a Typc lI Hood at the pizza <br />ovcn. <br />2. The roof plan sl�ould indicate which fans shown on M-1.1 are �['-1 and EP-2, and the <br />distance of a mininwm of 10 feel horizontally from air intakc openings into the building, <br />includ�ng adjxent tcnants, per IMC 5063.123. <br />3. I3uilding cross sections indicating iloor/cciling, roof/ceiling and wall constn�ction <br />adjacent to or penctratcd by "type I I�ood, t�rease duct and exhaust. <br />a. Indicate support of Type I hood to structure. <br />b. Grease duct systems and exhaust equipment: 3 inch clearance to gypsum <br />wallbomd/metal stud wall or l8 clearances to wood construction (altemate <br />reduction mcthods per Table 305.6 Z00G Intemationa] Mechanical Code). All <br />Type I hoods are required to have 18 inch cicarance from combustible wall <br />construction, per IMC 507.9, or the wall Uehind the Type I Ilood should be <br />identified as an existing metal stud wall. Altcmatc construc�ion methods for <br />combustible wood �valls are summarized on the nuached information shcet, as <br />excerpted from the IMC. <br />a Grease duct enclosurc: 6 i�ich clearance to gypsum wallboard/metal siud wall or <br />18 clearances to wood construction (alternate reduction method with one hour <br />fire resistance ratcd duct wrap for zero clearance). <br />CITY OF EVERE7-T • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 ,� <br />1�� <br />y �...ui�i�ynn��,n,;_..,_ i��,� rz� sc r,:«�� r.,.,u w.,,�,:: � <br />