Laserfiche WebLink
July 11. 1973 <br />�, Mr. Richard E. Seleine, Architect <br />; 511 East Balboa Blv1�. <br />j Balboa, California 82651 <br />RE: SIiEIi.MAN CLAY STQRE <br />EVERETT MALL <br />�-� EVERETT;'WASffiNGTON <br />Dear Mr. Seleine: <br />I�U'' <br />The follovring corrections muat be made to the drawings an3� <br />or specifi�ations before a permit can be iasued. <br />1. <br />2. <br />3. <br />4. <br />5. <br />Toilet rooms shail have smooth hard non-absorbeat <br />wainscat 4'-0" high. Enamel paint on gypaum <br />wall board does comply for walls. <br />Toilet rooms for both sexes are required. <br />Acoustic tile must be installed in accordance with <br />the U. L. approved design for a on.e-hour fire <br />resistive ceiling, <br />Recessed �lectrical fixture� must be rated one-hour <br />or protected. <br />Heating or air conditioning openings in ceilinga must <br />be fire dampered or protected, <br />g, Other openings, ruch as ec�vnd, etc. , must be protected. <br />7. A separate sign permit ruust �e �ecured for the sign. <br />A licensed sign hanger is x�equire3 to install the sign. <br />8, Furniah plumbing riser diagrams for waste an3 water. <br />a <br />10. <br />Submit mechanical drawings showing duct protection. <br />A sign must be posted at front folding door. "This door <br />mustbe open durin� business hours . <br />