Laserfiche WebLink
� <br />November 1, 19a3 <br />Planmark <br />Box 1243 <br />Minneapolis MN 55440 <br />Attn: Mike Bartliol <br />SIJB�ECT: PLAN RE4IEW <br />HAGGEN FOODS <br />EVERETT, WASHINGTON <br />PreliminarY notes <br />aTr or <br />everett <br />GIrvHALL n }53�0].L <br />EVGRETT, WAS�IINGTON <br />88�01 <br />INSP[CTION OEPMibAEHt <br />1. Incnmplate finish schedule. <br />2. Incomplete door schedule. <br />3. No overflow scuppers from canopy roof. <br />4. Drs 211A and 212A s�aing wrong way. <br />5. Catwalk has only 4'-4" headroom; l•lhere are st�irs for 2'-4" diff. <br />in fii . elevs? <br />6. How wida is corridor 204? <br />7. Is the building sprinklered? <br />8. What is slope of roof? <br />9. No stair information on any stairs (rise, run?) <br />10. Can't read notes on Sheet S-2 @ following locations: <br />Flo»r plan <br />Grid line F betw. 4& 6 and 8 to 11 <br />" " 6 " 5 & 7 <br />" " A " 1 & 5 <br />Office mezzanine <br />Grid line B betw. 3& 5 <br />11. Need detail re "diag. kickers -------". See note A betw. 3& 5. <br />12. Need column detail at intersection of roof trusses and steel beams <br />along Grid line Q. <br />13. My spot check of for,ting at Col. 7 shows there should be 9-#5. <br />Please sulxnit two ('L) copies of completed and corrected drawings. <br />_� <br />your very tr-uly, / <br />�/ tC'ck� � ;`�i�% <br />�a'ck E. Frets <br />�.Plans Er.aininer <br />cc: Haggen r'oods <br />