Laserfiche WebLink
Pl1BL/t f�VO/�/l'S <br />Sent via e-mail <br />8li ��/�� <br />/L�n � �.,� re�..��•.c� <br />•..,1—�1 <br />n��b��s� z�, 2o i o <br />Ms. Lnurn Lnra <br />I Iccry Architects <br />I I Golden Shorc, Suilc 550 <br />Long l3each, CA 90802 <br />projcct: "I'cn;mt Improvcment Mcdical Ofliccs Molina I Icnhhcarc <br />Job Addross: Sui�c 120, I S S�V livcrcu Mall Way <br />Plnn Revicw No: 131008-005 <br />Drir Ms. Lai:�, <br />In responsc lo your npplicalion for building conslruc�ion pcnnil, thc pinns h�rvc been cxamincd and you ��re <br />ndviscd Ihat n permit cnnnnt hc issucd un�il tlic fnllo�ving issucs nrc resolvcd. Plcasc providc a respunsc Icltcr <br />which shows �vhcrc cacli ilcm in this corrcction Icltcr is nddresscd on thc plan sct. For darilication, plensc cloud <br />nnd idenlify ��ny rcvisions �o Ihc ch:�wings as rcquired by lhis Icttcr. <br />Occupancy and 13uilding Cndc Infornu�tiai <br />� I. 'I'lic sitc nncl building inl'ormalion (codc dntn) on tihccl A-0.0 should ;ilso includc ihc 1'ollotving: <br />a. Currcnl :In�)IIC;IIIIC CO(ICS Ii511`(I 111 IIIC I10110111 U� 1815 IClil`I'. SEE COVER SHEET A-0.0. <br />b. Idcnlify occupnnt lond for thc tcnnnl improvcmcnt, bnscd on usc nnd squnrc foo�agc. <br />SEE COVER SHEET A�0.0. <br />T:SI'C55 <br />✓ I. 'i'hc ncw cxtcrior door rcquircd for common pnlh of travcl requirenicnts, per 1[3C scction 10 t 4.3, requires n <br />sign indicnting thal Uic clour is lu rcinaiu unlocked while Ihe building is occupicd, per 113C seclion <br />1008.19.3 psnngrnpl� 2.2. '1'he sign design and location requircmcuts should be shown on thc drn�vings. <br />SEE PARTITION PLAN SHEET A-2.0, KEYNOTE k24 AND �ETAIL N77/D-2.0 <br />r/ 2. 1'he lockset on door I I shoidcl be identified on Aic drnwings �s being rendily distinguishnble as bcing <br />lockcd, per 113C section 1008.1.93 pnmgraph 2.1. <br />SEE PARiITION PLAN SHEET A-2A, DOOR NOTES ADDED PER IBC SECTION 1008.1.9.3. <br />✓3 <br />� <br />Door 2 and 28 rcquire additionnl iniormation on the drnwings to indicate that the locksets arc rendily <br />opcnnbic from tlm cgress sidc without the usc of a kcy ore specini kno�vlcdgc or effort, per 1I3C section <br />I 008. I .9. <br />SEE PARTITION PLAN SHFET A-2.0, HAR�WARE NOTES ADDED PER IBC SECTION 1000.1.9. <br />All doors requirc nddiUonal informntion on �he di�nvings to indicnte thnt the door hardware docs nol <br />requirc tight grnsping, pinching or hvisting of the wrist to operate, per IDC scction 1008.1.9.1. <br />SEE PARTITION PLAN SHEET A-2D, DOOR NOTES A�DED PER IBC SECTION 1008.1.9.3. <br />It appenrs thnt some door clevntions rcferenceJ on Ilie floor pinm m�y be missing, incorrect, or incompletc <br />"fiic follo�ving infonnation is required on the dr�wings: <br />✓ • Door hardware height, per lI3C section 1008.1.9.2�SEE PARTITION PLAN SHEET A-2.0, DOOR TYPE, ELEVATION A <br />v• Visian lites (if any) per II3C A I 17.1 section 404.2.10, NOT APPLICABLE <br />� e DO01' S1%C, �)CI' I�.iC SCC11011 I OOS.I.I. SEE PARTITION PLAN SHEET A-2.0, DOOR TYPE, ELEVATION A <br />,� G. Illuminnted cxit signs aro required in thc corridor nccessing thc medicnl officcs per IBC section 1011.1. <br />Thc e�it sign locntions sl�otdcl 6e shown on the drnwings. <br />SEE REFLECTED CEILING PLAN SHEET A-3 0, ILLUAIINATED EXIT SIGNS ARE PROVIDED AND SHOWN. <br />ENGINE[RING / PUBLIC SERVICGS DIVISION • 3200 Cedar Slreel • Everelt, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 � <br />