My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 SW EVERETT MALL WAY EVERETT POWER SPORTS 2018-01-02 MF Import
>
Address Records
>
SW EVERETT MALL WAY
>
215
>
EVERETT POWER SPORTS
>
215 SW EVERETT MALL WAY EVERETT POWER SPORTS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:15:55 AM
Creation date
2/10/2017 2:22:46 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
215
Tenant Name
EVERETT POWER SPORTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C (. <br />Everett Powersports <br />Plan Check No.: B0005-026 <br />4) The one -hour occupancy separation between the B (showrooms) and S-3 areas should <br />be revised as noted below:... <br />p) See revised door schedule Sheet A7. 1-hour note has been added to door <br />N9. <br />fler Ccj""'S '�i/ All occupancy walls have been labeled on plans. See revised sheet A2 & <br />A3. <br />c) 1-hour occupancy separation f oor/ceiling assembly has been added to <br />Jthose floor areas where occupancy separation walls are not continuous <br />vertically. Please see revised plans A2, A3, bldg. section on A5, and added <br />/ section 4/A8 for construction information. <br />v d) Please see attached NER-200, section 3.5.2 Assembly B for 1-hour TJI <br />Joist floor -ceiling construction. See detail 4/A8 for floor construction <br />information. <br />el The walls/columns supporting the 1-hour floor/ceiling assembly have been <br />revised to reflect 1-hour construction. See added detail 5/A8 for 1-hour <br />column wrap assembly and general note N4 on sheet A2. Please note that <br />detail 5/A8 is based upon UL Design 0OX528. <br />f) All duct penetrations through the occupancy separation walls & <br />floor/ceiling assemblies will have smoke/fire dampers installed per <br />Sections 713.10 & 713.11, no exceptions taken. Mechanical contractor to <br />submit final engineered mechanical design drawings to you for review & <br />approval prior to construction. <br />5) The sprinkler room is not consistent with the size and location requirements noted in <br />Everett Standard 523 (attached). <br />The sprinkler has been relocated to provide direct access from the exterior of the <br />building and resized to accommodate the double check detector valve assembly. <br />1/6) Details for the removable guardrail should be provided Calculations verifying the <br />loads required by Table 16-B should be included. Section 509. <br />Please see added detail WAS for guardrail construction information and attached <br />/ structural calculation as requested. <br />7) Fire Blocking should be shown at the intersection of the interior walls and the dropped <br />ceiling (see details I/A7). Section 708.2.1. <br />See revised detail 1/A7 and building section 2/A5 for required fire blocking. <br />
The URL can be used to link to this page
Your browser does not support the video tag.