My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
223 SW EVERETT MALL WAY 2016-01-01 MF Import
>
Address Records
>
SW EVERETT MALL WAY
>
223
>
223 SW EVERETT MALL WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 5:05:58 PM
Creation date
2/10/2017 2:24:23 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
223
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TO: <br />FROM: <br />DATE: <br />SUBJECT: <br />PU�L/C W0/4/ffS <br />Wetpond/Detention: <br />MEMORANDUM <br />AI Locke/Gordon Witcher <br />Jane Zimmerman <br />July 23, 1996 <br />Drainage Calculation Review, Everett Honda, Everett Mall Way <br />The stage-storage relationship of the wetpond is required to show that the pond has the <br />capacity to store the required wetpond permanent storage volume. <br />The design depth of dead and live storage in the wetpond must be given in the calculation <br />package. The open wa[er cell is required to have a dead storage depth of 3-6 feet, the wetland <br />treatment cell may have a maximum average depth of 1.33 feet. <br />The City standards require a minimum of 50% of the wetpond design volume to be provided <br />'�� % we po d design s orm (the 6 monthh24-hour sto�o)d�deQsllgn�vol�e �et ond desien storginhe <br />�•, <br />i' '�. developed hydrograph through the pond_is required to_v_erify_thatihe wetpond-design�alu�ne <br />% is reached for the wetpond design s[orm. -The size of the primary orifice can be decreased as <br />necessary, to a minimum allowable orifice size of 1 inch, [o achieve enough live storage. If a <br />i inch orifice doesn't result in the required storage in the pond, then the percentage of the <br />wetpond design volume provided as dead storage must be increased until the combination of <br />dead storage and peak live storage (during the wetpond design storm) equals the wetpond <br />design volume. <br />The control structure(s) must ensure that detention release rates do not exceed allowable <br />release rates � that the detained volume in the pond reaches or exceeds the wetpond design <br />volume for the wetpond design storm. Orifice calculations must be submitted showing that the <br />control structure meets both these requirements. <br />Since high flow velocities are generally not a concern in the wetpond, the storm sys[em should <br />not be designed to bypass high tlows around the wetpond. With a bypass in place, short- <br />intensity storms with a low volume but high peak flow will mostly bypass the pond. These <br />types of storms wash a lot of pollutants off of paved surface and must be conveyed to the <br />wetpond. <br />Orifice sizine: <br />Non-publicly maintained restrictor devices may have a minimum orifice size of 1 inch. <br />
The URL can be used to link to this page
Your browser does not support the video tag.