OTaT&KOSENAU & ASSOCIATES, INC. <br />Geotechnical Engineering, Construction Inspection & Materials Testing <br />PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT <br />Job Number: 12-0004 Report Number: 249244 Permit Number: B1109-026 <br />Project: Everett Floral Client: Tersuli Construction Services, LLC <br />Address: 4522 Evergreen Way, Everett Address: 1416 NW 46r" Street— Suite 105, PMB #338, Seattle <br />Inspector: Mark Gray Date: 02/29/2012 <br />Description/Location: East and South wall of Annex, located on the west side of existing building; install beam connections via all - <br />thread rods to angle iron per detail 7, sheet 5 of approved plans supplied by contractor. <br />Mdhii.n Cndp P. Yeac IBC 2009 <br />mrenueu Esc. r',c,n "U —I.— <br />❑ Reinforcing Steel <br />13 All Thread <br />Bar/Dowel Size & Quantity: <br />Anchor Size & Quantity: (20) %" <br />Rebar Manufacturer: <br />Type of Steel (ASTM): ® A-36 ❑ A-325 ❑ A-449 <br />❑ Other: <br />Rebar Grade: ❑ 40 ❑ 60 ❑ Other: <br />Type of Bar: ❑ A-615 ❑ A-706 <br />❑ A-775 ❑ Other: <br />Special Ductile Quality (SDQ): <br />❑ Yes ❑ No <br />Anchor Length: 8" <br />Hole Depth: 5" <br />Required Embedment: 5" <br />Hole Diameter: 3/4" <br />Concrete Thickness: N/A <br />Concrete Strength: N/A <br />Base Material: ❑ Normal Weight Concrete ❑ Light Weight Concrete ® CMU ❑ Brick ❑ Composite Deck <br />Hole Cleaning: ® Compressed Air <br />❑ Hand Pump ❑ Other: <br />Compressed Air PSI: 110 <br />Brushed: ® Yes ❑ No <br />Hole Condition: ❑ Dry ® Damp ❑ Water Saturated ❑ Submerged <br />Drill Bit (ANSI B212.15): ® Yes <br />El No <br />Approved Diamond Cored Hole: ® Yes ❑ No <br />Adhesive Type: Simpson ET22 <br />Expiration Date: 12/2012 <br />ICC ESR #: 4945 <br />Weather: Rain <br />Ambient Temperature: 41' <br />Substrate Temperature: 40' <br />Vv...... O.. <br />Contacted Pacific Engineering about northeast corner angle and separate south wall location where only 3'/2" embedment was <br />achieved. Engineer verbally issued approval to proceed with the existing field conditions not meeting plan details. <br />Reference Standard(s) Used: Conforms x Does Not Conform <br />Copies to: <br />Client Engineer Others�'A <br />Owner x Contractor Technical Responsibility: <br />Architect X Building Dept. Jen Rabe, Project Manager <br />This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, <br />except in full, withal written permission from our firth is strictly prohibited. <br />Page 1 of <br />6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 7254600 or 1-888.OTTO-4-US — Fax (206) 723-2221 <br />Form No.: ADMIN-86-01 (Rev 09109) <br />