SENAU & ASSOCIATES, INC. <br />Ideotechnical Engineering, Construction Inspection & Materials Testing <br />MASONRY REPORT <br />Job Number: 12-0004 <br />Report Number: 248988 <br />1 Permit Number. B1109-026 <br />Project: Everett Floral <br />Client: Tersuli Construction Services, LLC <br />Address: 4522 Evergreen Way, Everett <br />Inspector & Date: Jim Reid 1/9/2012 Masonry Sub or Contractor: <br />DESCRIPTION / LOCATION <br />IBC Level of Inspection: Level 1 ® Level 2 ❑ SBC Level of Inspection: Level 1 (Periodic) ❑ Level 2 (continuous) ❑ <br />(Projects located outSeattle) Ref. 17-04.5.1/17-04.5.3 IBC 2006 (Projects located in Seattle) Ref. 17-04.5.1/17.04.5.3 SBC 2006 <br />Arrived on -site as requested to perform an inspection of 8-inch CMU masonry wall at the southwest comer of the building per; 11 <br />details on Sheet 3 and General Notes (second lift). Checked reinforcing for type, grade, spacing, splice length and minimum <br />cover. All cells were hand grouted. To the best of my knowledge the inspected area listed above conforms to the approved <br />plans and specs. <br />Approximate square footage completed on this date: 140 <br />Are anchors in place? (if required) : n/a <br />Was reinforcing steel verified? Yes <br />Is reinforcing steel secured in place?: No <br />Grade of reinforcing steel: 60 <br />Manufacturer: Cascade <br />Is high lift grouting approved?: n/n <br />GROUT INFORMATION jAbTM C WItt (exdudnapergaph12-1.6) <br />Mix no./type: Mutual Materials Grout supplier: Mixed on Site Grout preparer: Mason <br />Grout temperature: 55" Grout slump: 8.5" Total yardage: unknown Method of consolidation: Mechanical <br />Grout ingredients & weights: Premix, 60# bag <br />a <br />MORTAR INFORMATION ASTM C 780 <br />Mix no./type: Design Mix / S <br />Mortar supplier: Mixed on Site Mortar preparer: Mason <br />Mortar temperature: ? Mortar ingredients: Premix <br />MATERIAL INFORMATION ASTM C 67/ ASTM C 140 <br />Block/unit supplier: Mutual Block/unit type: 8" CMU <br />SAMPLE INFORMATION 7 <br />Were any samples made? Yes I <br />If Yes —see attached report <br />OTHER <br />INFORMATION <br />Weather & ambient temperature: Overcast, 49' <br />Protection methods: <br />Is this a re -inspection? No If yes — original inspection date: <br />COMMENTS ' <br />1 set of 3 prisms were made. <br />Other ASTM Methods Used: Conforms X Does Not Conform' VP <br />Copies to: <br />Client Engineer Others �,fn�I. ''�r, <br />Owner X Contractor Technical Responsibility: YIM.YVw7 <br />Architect X Buildin.J Dept. Jeff Rabe, Project Manager <br />This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, <br />except in full, without written permission from our fine is strictly prohibited. <br />Page 1 of 2 <br />6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 or 1.888-OTTO.4-US — Fax (206) 723-2221 <br />Form No.: ADMIN-72-06 (Rev 02111) <br />