Laserfiche WebLink
0'� T O. ROSENAU & ASSU IATES, INC. <br />Geotechnical Engineering, Construction Inspection & Materials Testing <br />MASONRY REPORT <br />Job Number 12-0004 <br />Report Number: 240357 <br />Permit Number. B1109-026 <br />Project: Everett Floral <br />Client: Tersuli Construction Services, LLC <br />Address: 4522 Evergreen Way, Everett <br />Inspector & Date: Darren Reid <br />Masonry Sub or Contractor: <br />Tersuli Construction Services, LLC <br />DESCRIPTION <br />/ LOCATION <br />IBC Level of Inspection: <br />(Projects located outside Seattle) <br />Level I ® Level 2 ❑ <br />Ref. 17-04.5.1I17-04.5.3 IBC 2006 <br />SBC Level c' Inspection: <br />(Projects located in Seattle) <br />Level 1 (Periodic) ❑ Level 2 (Continuous) ❑ <br />Ref. 17-04.5.1I17.04.5.3 SBC 2006 <br />Reinforcing steel and grout placed per approved project documents a 8-inch CMU wall, south end, west side third lift to top of <br />wall. <br />Approximate square footage completed on this date: 150 <br />Was reinforcing steel verified? Yes <br />Are anchors in place? (if required) : Yes <br />i. <br />Is reinforcing steel secured in place?: Yes <br />Grade of reinforcing steel: 60 <br />1 Manufacturer: - Cascade <br />Is.high lift grouting approved?: No <br />GROUT INFORMATION ASTM C 1019 (a iuchngparagraph 12.1.e) —+ <br />Mix no./type: Lafarge Grout supplier: Mutual Materials I Grout preparer: Mason <br />Grout temperature: 43' Grout slump: 10" 1 Total yardage: n/a Method of consolidation: Batt Vibrate <br />Groin ingredients & weights: 60 Ito bags to water as required <br />MORTAR INFORMATION JAb TM C 780 <br />Mix no./type: 5 Mortar supplier: Design mix Mortar preparer. Mason <br />Mortar temperature: Mortar ingredients: Pre -proportioned bags <br />. MATERIAL INFORMATION ASTM C 67/ ASTM C 140 <br />a <br />Block/unit supplier: Mutual Materials <br />Block/unit type: B" <br />SAMPLE INFORMATION <br />Were any samples made? No <br />If Yes — see attached report <br />OTHER <br />INFORMATION <br />Weather & ambient temperature: Light overcast <br />Protection methods: <br />Is this a re -inspection? No <br />If yes — original inspection date: <br />COMMENTS 'ram <br />Other ASTM Methods Used-7Conforms X I Does Not Conform <br />Copies to: <br />Client Engineer Others <br />Owner X Contractor Technical Responsibility: <br />Architect X Building Dept. FVJeff Rabe, Project Manager <br />This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, - <br />except in full, without written permission from our firth is strictly prohibited. <br />Page 1 of 1 <br />6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 or 1-888.OTTO.4-US — Fax (206) 723.2221 <br />Form No.: ADMIN-72-06 (Rev 02/11) <br />