My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10115 EVERGREEN WAY OFFICE DEPOT 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
10115
>
OFFICE DEPOT
>
10115 EVERGREEN WAY OFFICE DEPOT 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2020 8:51:16 AM
Creation date
2/10/2017 7:02:16 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10115
Tenant Name
OFFICE DEPOT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
148
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/C if/ORKS <br /> May 21, 2013 ----i <br /> Sent vic� e-mai� i <br /> Mr. Gougal Thomas S/ 2.��2u I) � <br /> West Mechanical, Inc. _ <br /> 4443 Alorich Road <br /> Sellingham, WA 98226 <br /> Project: Office Depot Store #982 <br /> Job /�ddress: 10115 Evergreen Way <br /> Plan Review: M1305-001 <br /> RE: Second corrections letter <br /> Dear Mr. Thomas, <br /> In response to your application for a mechanical construdion permit, yoi�r plans have been examined and you <br /> are advised this is still an incomplete submittal. Upon submission of two sets of inechanical drawings <br /> reflecting the information requestPd, your application will be given priority and plan review will resume. <br /> 7his information was also noted in the first corrections letter sent by e-mail on May 8, 2012. I have included <br /> some examples of the type of inechanical drawings that are required for a mechanical permit for rooftop units, <br /> at your request. <br /> Mechanical <br /> 1 All submittals should include (as applicable) the following on the mechanical drawinqs: <br /> a. Locations and legend references for all new mechanical units. <br /> b. Cubic feet of air per minute (CFM) at each air diffuser, return air register; exhaust and trensfer <br /> grill; size of ducts and outiets; equipment schedule of brand names, fuel type, model numbers, <br /> input and output capaciry, tons of cooling, efficiency ratings, CFM capacity, motor efficier.cies, <br /> and unit��eights; and locations of smoke and fire dampers. <br /> c. Combustion air source, size and !ocations, if aoplicable. <br /> d. Make-up air system required to meet IMC, WSEC requirements. <br /> e. Roof parepet and screening, where applicable or required. Please contact the Planninq <br /> Denartment to discuss. Teresa Firnstahl can be reached at 425-257-7281. <br /> 2. An economizer is required for the new mechanical air I•iandling units, unless documentation is provided <br /> otherwise indicating conformance with WSEC section 1424 Economizers. <br /> Applicable codes include the 2009 international Building Code, the 2009 International Fire Code, the 2009 <br /> International Mechanical Cude, and the 2009 Washington State Energy Code (WSEC). All codes referenced, as <br /> adooted by the City of Everett, should include current revisions by the State of VJashington. Revisions or <br /> additions may be required by other departments (such as Utilities, Flanning, or Fire). Please contact ��ie if <br /> you would like to disass this letter by e-mail at mha!evC�ci.everett.wa.us or by phone at 425-257-8813. <br /> Sincerel <br /> � � . .. . , <br /> / �`. <br /> Meg Ha y, NCARB <br />
The URL can be used to link to this page
Your browser does not support the video tag.