Laserfiche WebLink
. � f I <br /> ENG/NEER/NG/�UBL/C SERY/CE5 DEPARTA/ENT <br /> S,. <br /> Jaly 3Q 2008 <br /> Ms.Julic Mardis <br /> Linn-Douglas Conslructior, LLC <br /> PO Box 8019 <br /> Covington, WA 98042 � <br /> i <br /> Project: Quality Scwing�Vacuum r <br /> Job Address: 1012] Evergreen Way#15 <br /> Permit No: L0807-041 <br /> Dear Ms. Mardis, <br /> In response to your application for building construction permit,the plans have becn examineu and you are !, <br /> advised thr.t a permit cannot be issucd until ihe following issues are resolved. Picase providc a response letter <br /> which shows wherc cach itcm in this corrcetion letter is addressed on the plan set. For clarification,please <br /> cloud and identify any revisions to the drawings in response to this Ietter. <br /> Construction: <br /> /1. A Washington Statc liccnscd enginecr or a licensed architcct must verify that�roposed openings in the i <br /> former demising wall behveen tenants and modifications/demolition of the existing east-west walls ` <br /> would not reduce thc latcral and gravity force��sisting systems of the building below what is currenAy i <br /> required by thc building codc. This should bc done in either a writtcn letter for a non-shvctural wall,or I <br /> with calculations for a building shear walls. � <br /> ✓ 2. Dclails of how the two new openings in thc former demising wall should be shown on the drawings , <br /> indicating hmv the opening will be framed, identifying the grade, material and dimensions of the header <br /> and Qie support of the hcader. � <br /> '/3. A ncw slat wall is referenccd on thc drawin@s Sut not detailed. ICthis wall is higher than 5 feet 9 inches, <br /> then a wall section should be indicated on the drawings,per IBC section 105.2. <br /> �4. The Uuilding standard par;ition section shown on the drawings should be keyed to the new walls in plan <br /> for clarification. � <br /> i <br /> `��. Since the square footage of thc tanant space exceeds 4000 square feet, by Washington State law a � <br /> licensed architect must prcparc and stsmp thc drawings,per RCW 18.08.410(6.). � <br /> �6. The mercantile arca uscd by thc pubiic is calculatcd at 1 person per 30 b�ross square fcet, per 1BC table <br /> ]004.L 1. Thc classroom arca is calculated at 1 person per 20 net square feet. The combination of these <br /> calculations �vould incrcase the occupant load from what is currendy shown in the code analysis to over <br /> 100 accupants. <br /> �I� <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425} 257-8856 <br /> ti�\IIIaIcy6�brd�60B0]�OJ I 10121 Eva6��m N1y v�y�a <br />