Laserfiche WebLink
5. The cover sheet sh�uld note the Type of Construction, Builu�ng azea(new and <br /> additional), Occupancy Type and Occupant load. <br /> 6. An approved automatic fi�e suppression system should be provided for the new and <br /> existing portions of the building as the area exceeds 6000 square feet. City of Everett <br /> Ord. 1902-92 <br /> 7. An approved, monitored fire detection system should be provided for the new and <br /> existing portions of the building as the area exceeds 3000 square feet. City of Everett <br /> Ord. 1902-92 <br /> 8. Two copies of the plans and calculations for the metal building should be submitted <br /> for review <br /> 9. An exiting diagram for the existing building should be provided. <br /> 10. The location of the va,�-accessible customer parking space should be noted on the <br /> plans. Section 1107.1.5 <br /> 11. It should be clazified whether or not the service write-up will be a heated, or unheated <br /> space. Section 1301,I�TREC <br /> 12. Insulation values should be called out on the plans. <br /> Please prepare a response letter sriowing where each item in this letter is addressed on the <br /> plan set. <br /> Upon submittal of the drawings, you application will be given priority aud plan review <br /> will recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to <br /> ensure that the proposed structure will be constructed in compliance with all adopted <br /> codes. <br /> Sincerely, , <br /> ��— <br /> .� � / c , i— <br /> Tony Lee�/ <br /> Associate Engii.eer <br /> TL:jt:b0006-048 <br /> ? �y <br />