Laserfiche WebLink
7. Properties to the south and east of the proposed warehouses are , <br /> designated for residential use. Substantial landscape screeninq <br /> ' must be provided along both property lines. Landecaping shall <br /> consist of sufficient everqreen trees or shrubs a minimum of 6 <br /> feet in height to provide a sfqht obscurinq barrier. Plantinqs <br /> shall be offset within a 15 foot wide plantinq area. In <br /> additlon, plantings must provide sufficient vertical elements to <br /> break up the appenrance of bulk of the buildings. (SEPA Land and <br /> Shoreline Use Policies) <br /> 8. Everqreen Way is desiqnated in the City's General Plan as a <br /> "qateway" corridor to the City of Everett. The Plan policies <br /> encourage that siqnaqe in qateway areas be regulated. A unified <br /> siqninq plan for this proposal must be reviewed and approved by <br /> the Planninq Department prior to the issuance of any sign <br /> parmits. One free standinq pole � qround siqn shall be <br /> permitted f�r this sita. The size of the pole siqn shall be <br /> limited to no more than 100 sf per side and no more than 25 feet <br /> in heiqht. The size of a ground siqn will be limited to no more <br /> than 100 sf per side and no more than 15 feet in heiqht. All <br /> other siqns shall be attached to the face of the buildinqs and <br /> shall not exceed the height of the roof of the buildinqs. None <br /> of the siqns shall be animated or illuminated by intermittent <br /> liqht sources. ]�r►y readerboards shall be incorporated into the <br /> sinqle qround or buildinq siqn. No free standinq readerboards <br /> will be permitted. (SEP�1 Land and Shoreline Use Policies) <br /> lQTIG7ITIOIf RBQUIR� BY 87CISTIliG OODBS 11ND ORDIN71tICS3 <br /> 1. A fire hydrant is required within 200 driving feet but not closer <br /> than 50 feet, of evezy structure. Two hydrants are required <br /> for this project. The fire flow requirement is 1,750 qallons per <br /> minute. (SEP1� Public Services and Utilities Policies) <br /> 2. Any broken or damaqed sidewalk shall be repaired/replaced per the <br /> City Public Worka Inspector. (SEPa Transportation Policies) <br /> 3. 11 55 foot driveway must be installed per City Standard 307. <br /> (SEP1� Transportation Policies) <br /> 4. Special charqes for connection to the sewer system in accordance <br /> with Ordinance 984-83 are applicable. The actual cost shall be <br /> computed by the building Department per the ordinance in effect <br /> at the tima and according to the information provided on the <br /> approved plans on the date of permit issuance. (SEP1► Public <br /> services and Utilities Policies) <br /> 5. Parkinq must be per City Zoninq Code and City Desiqn and <br /> Construction Standnrds. A minimum of 3 parkinq spaces plus one <br /> for each three employees are required. (SEPA Transportation <br /> Policies) <br /> 3 <br />