Laserfiche WebLink
koj <br />PERFORMANCE: INFLOW TARGET -OUTFLOW ACTUAL -OUTFLOW PK-STAGE STORAGE <br />DESIGN HYD: 6.35 1.16 1.20 12.01 50226 <br />TEST HYD 1: 4.34 .57 .50 11.36 47520 <br />TEST HYD 2: 2.59 .11 .10 7.71 32240 <br />STRUCTURE DATA: R/D-VAULT <br />RISEP:-HEAD VAULT -BOTTOM -AREA STOR-DEPTH <br />12.00 FT 4183.1 SQ-FT 12.00 FT <br />DOUBLE ORIFICE RESTRICTOR: <br />BOTTOM ORIFICE: <br />TOP ORIFICE: <br />ROUTING DATA: <br />STAGE(FT) <br />.00 <br />1.20 <br />2.40 <br />3.60 <br />4.80 <br />6.00 <br />7.20 <br />8.40 <br />9.60 <br />10.80 <br />11.00 <br />12.00 <br />12.10 <br />12.20 <br />12.30 <br />12.40 <br />12.50 <br />DISCHARGE(CFS) <br />.00 <br />.04 <br />.06 <br />.07 <br />.08 <br />.09 <br />.10 <br />.11 <br />.12 <br />.12 <br />.12 <br />1.16 <br />1.67 <br />2.57 <br />3.71 <br />5.05 <br />6.56 <br />DIA(INCHES) <br />1.18 <br />6.16 <br />STORAGE(CU-FT) <br />.0 <br />5019.7 <br />10039.5 <br />15059.2 <br />20078.9 <br />25093.7 <br />30118.4 <br />35138.1 <br />40157.8 <br />45177.6 <br />46014.2 <br />50197.3 <br />50615.6 <br />51033.9 <br />51452.2 <br />51870.6 <br />52288.9 <br />H STORAGE -VOLUME <br />50226 CU-FT CAL-G' O <br />HT(FEET) Q-MAX(CFS) �2"1D VVZWW 15 <br />.00 .130 _� <br />11.00 1.030 <br />fi 'fix ore <br />PERM-AREA(SQ-FT) <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />.0 <br />AVERAGE VERTICAL PERMEABILITY: .0 MINUTES/INCH <br />