. ' �� ( <br /> detail, and must bc intemally consistent. Riser diagams must match instullation plans and load <br /> calculations. Components must bc listed and approved for use together. Changes to plans must <br /> include new drawings and calculations and must be approved by the Fire Deparhnent Plan Reviewer <br /> prior to installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the En�ineering&Public Services Departnent electrical <br /> permit must be present for any installation inspection. <br /> Fire alarm systems shall Ue instnlled under petmit of the City of Everett Engineering&Public <br /> Services Deparlment. Electrical inspections and approval are required prior to calling for acceptance <br /> tests. Call (425)257-8810 for permit inFormation. <br /> The absence of worktng phone lines for the alarm system will be causc for postponing Fire <br /> Department tnspection and testing and shall result in denial of occupancy. <br /> 8, Fire Suavression(Sprinklerl Svstem -An approved automatic suppression systcro shall be provided <br /> as required by City Ordinance No. 3021-07,Chapter 16.76,of the Everett Municipal Code. The <br /> system must include a mechanicai water gong bell. <br /> Plans for any such system shall be submitted tu the Engineering& Public Services Department for <br /> examination and approval. Such plans shall include plans for the undergound mains that will supply <br /> the sprinkler system. <br /> The type of sprinkler to be instulled will be determined by the Building Official. It may be an NFPA <br /> 13,NFPA 13R,or NFPA 13D system depending upon several factors. Sprinkler installation shall <br /> not begin without an approved and stamped set of plans from the Engineering& Pubdc <br /> Scrvices Department. The Fire Department will also review thc plans and shall field inspect the <br /> installation based only on approved plans that must be on site. Chunges to plans must be approved by <br /> both the Engineering&Public Secvices and Fire Departments. <br /> Above�'ound sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Stundard 24 <br /> for private fire mains. (Below eraund afaine must be Installed bv Nashineton State Patrol <br /> Licensed Undereround Sarinkler line certified "U" installere. For further mformatlon, contact <br /> the State Fire Marshal's Office at (360) 570-3134 or contact the Everett Fire Department at <br /> (425)257-8124.) All such tests shall be witnessed by a Fire Department [nspector. Call (425)257- <br /> 8126 to make an appointmcnt for inspection. <br /> Contractors'matcrials and test ceRificates shall be submitteJ to the Everett Fire Department prior to <br /> issuuncc of any CcRificatcs of Occupuncy. <br /> Call (425) 257-8124 for more information. <br /> ). 1'rcmise Identificution - Premises shnll be cleurly identified by the correct address at the street entry. <br /> Buildings shall be cicarly idcntifieJ so as to be visible and legible from the access road. Individunl <br /> apartments and suites, where applicable, shall be clearly and legibly identified from the uccess roed. <br /> Provide 8-irtcli address numerals on the building and 4-inch numerals for suite numbers on front and <br /> back doors. <br /> �o � /_�� 1' 1 <br />