\ <br /> . .-.� <br /> Mr. Sn�ce Vanderwall <br /> • Ap�ll 16, 2008 <br /> I <br /> The contractor may find that it is more expeditlous to remove alt of the fllls from under <br /> � ( the pad in the old fill areas if there are too many trenches based on the new foundadon <br /> locations. The Individual overexcavated trench margins should be extended laterally <br /> beyond the fatlng perimettrs. The trenches should be wide enough to provide an <br /> influence line extending dewnward and outward at a 0.5:1 (H:V) betow the base of the <br /> fouting. This would mean that where four feet of fill exists below the footlng grade, the <br /> -• trench would need to be two feet wider tt�an the inside and outside foodng edge. The <br /> variable depth of the flll will determine the varying depth of the fills. <br /> Some foundation areas for the new buliding may require over excavatlon due to the <br /> .. presence of unforeseen utility trenches, buried topsoil and o:ganic pockets, or other <br /> . poorly tompacted old fills. Foundation subgrades in these areas can be brought back bo <br /> � � grade with compacted structura� FlII or clean ballast rak. These areas m�y not become <br /> evident undl demolidon fs complete and some subgrades are exposed. <br /> Foundatlon subgrades should be prepared as recommended in the Site Preparadon and <br /> Greding sectlon. Perimeter foundations should extend at least 1.5 feet below final <br /> exterior grades for frost protection. Interlor foundations can be constructed at any <br /> � convenient depth. All fooUng e�ccavations should be thoroughly recompacted w{th hand <br /> equipment following excavation disturbance. <br /> For footings bearing on shallow native soils or on compacted structural fill or rock, w2 <br /> recommend designing foundations for a net allowable bearing ppacity of 2500 pounds <br /> per square foot(ps�. Foundations for the building based at deeper depths on the tlll or <br /> for the new storm water vault extended to the tlll may be designed for an allowable <br /> bearing capadty of 5,000 psf. All foundations, including interior column footlngs, <br /> should be a minimum of 1.5 feet wide. For short-term loads, such as wind and seismic, <br /> a 1/3 increase (n this allowable capacity can be used. <br /> Based on the soil conditions observed in the borings and the local seismicity, the site <br /> fails in Site Class D, in accordance with the 2006 Internadonal Buflding Code. Also, <br /> based on our review of the soil conditions, the potential for soil Ifquefaction to occur on <br /> this site is low. <br /> LaYeralloads <br /> For designing foundations to resist lateral loads, a friction coefficient of 0.4 can be used. <br /> Passive earth pressures acting �n the sides of the footings and buried portions of the <br /> foundatlon stem walls can also be considered. � <br /> Project No. 1235- \ <br /> Page Nd 7���% <br />