Laserfiche WebLink
. f <br /> C � � � <br /> EN6/NEER/NG;�PUBlJC SERY/CE5 OEPARTiNENT � <br /> � <br /> C <br /> � <br /> � <br /> May 5,2U08 � <br /> Mr.Randall Wong I <br /> ?314 Alamo Place South <br /> �verett WA 98087 <br /> Project: Phd Noodle I <br /> Job Address: 11632 Evergreen Way <br /> Plan Review No.: B0804-048 <br /> Dear Mr.Wong, <br /> T'hank you for your submittal. In response to your application for building construction permit,the plans have <br /> been'examined and yuu are advised that a permit cannot be issued until the following issues aze res�lved. <br /> Upon submission of two sets of revised drawings reflecHng the corrections requested,your application will be <br /> processed. <br /> Arc6itectural: � <br /> 1. The existing building shell permit(attached) indicates a conshuction type of IIB. 1'he only exceptions i <br /> allow for wood under that consWction type is noted in IBC s�ction 603.1 (attached). Please revise the <br /> wood studs to metal studs,unless the wood is fire-retardent treated and noted as such on the drawings. <br /> 2. The section indicates a partial height metal stud wall and the plan indicates a full height metal stud wall <br /> at the hood. Please clarify. I <br /> i <br /> 3. The commercial electric rice cooker should be located undemeath a Type II hood, or the Type I hood <br /> should be extended to e ver the rice cooker by at least six inches, per IMC section 507.2 and IMC <br /> 507.12. <br /> i <br /> 4. The dishwa<her will require a Type II hood unless it is identified as an under the counter dishwasher, � <br /> per IMC SC7.2.2 � <br /> 5. The deferred T,ype I hood permit submittal should indicate all of the attached requirements. For <br /> example, the location of the hood termination should be indicated on a roof plan to verify that a <br /> minimum 10 foot separation is maintained from the Type I hood exhaust from the make-up ai� required <br /> for this tenant and other tenants' intake air,per IbfC 506.3.12.3. ' <br /> I <br /> 6. Iadustria] pre-treatment (IPT) should be ccntacted to discuss the grease trap shown on the drawings. � <br /> Charles Johnstone,IPT, can be reached at 425-257-8224. <br /> Applicable codes include the 2006 Intemational Building Code(IBC),the 2006 Inte`ma6onal Fire Code(IFC), � <br /> the 2006 Intemational Mecaanical Code(IMC), the 2006 Washington State Energy Code(WSEC),the 2006 <br /> Washir.gton State Ventilation and Indoor Air Quality Code(VIAQ),and the 2003 Accessible and Usable <br /> l�uildings and Facilities A117.1-2003 (ICC/ANSn. All codes referenced,as adopted by the City of Everett, <br /> should include current revisions by the State of Washington. 1'hese comments address building issues only. <br /> Revisions or additions may be required by other departrnents(such as UHlities,Planning or Fire). <br /> � <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8656 �/Z ' <br /> 7 <br />