My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8530 EVERGREEN WAY MAGIC DRAGON 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
8530
>
MAGIC DRAGON
>
8530 EVERGREEN WAY MAGIC DRAGON 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2017 12:51:43 PM
Creation date
2/10/2017 12:51:34 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8530
Tenant Name
MAGIC DRAGON
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . . � � <br /> !. Makeup air �, .2� <br /> ctm. <br /> 1. Applicant shall provide makeup air not less than 9�qe Of Ihe e:chaust. _.__.___�i�-�. <br /> 2. Makeup air system shall be electrically interloc{ced with the axhaust��,�:�:n'�• "1`,'jan�he�;�o3keup air <br /> system will operate when the exhaust system is in operation. Provir:- �:; . ��� � <br /> 3. Makeup air shall be provided by a tan or motorized darrper of sufficieni capar,ity, Windows and docr <br /> openings shall not be used for the purpose of providing rr�akeup air. <br /> 4. If more!han 2500 c(m supplied to the spaco other than the hood, provide heater capable of heating t <br /> makeup air supplied to the space to Pd[BTUs=— Output BTU — <br /> 'rlea;ar model # AFUE <br /> Heater CFM _�— <br /> � 0�v�H�v <br /> FAN �/ (i R�j�� �Z�i�� MOTO ZED DAMPER <br /> � 'V H,p Recommended air velocity, 500(pm <br /> Make and model <br /> Static pressure ti in. at cfm. Duct area req. = cfm1500(pm /500 =_h2 <br /> Duct Dimension ����� arja�ftZ Duct. Dimension req. _ <br /> Air velocity = cfm/area��� I��� Eff. Damper opening <br /> x_ = ftz <br /> _ �G�po fpm • <br /> �. Siope of duct and cieanout access �/� <br /> ro osed �— inlft <br /> 1. Horizontal duct Iess than 75'long min slope 1/4 inlft proPo;,ed _— 'n�'� <br /> ' more than 75'long min slope 1 inlft P P ' <br /> 2. Tight•fitting deanout doors shall be provided at Total no. proposed ' <br /> every change in duclwork direclion. <br /> K. Duct enclosure <br /> 1. Ducts penetrating a ceiling,wall or iloor shall be enclosed in a duct enclosure from the point of <br /> penetration to the outside air. A duct may oniy peneVate exterior walis at locations where unprotected <br /> openings are permitted by Table 5A of the 1997 Seattle Building Code. <br /> 2. For code compliance purposes, R is acceptabie to assume ihat ducts peneVaGng concrete, brick or steel <br /> ceilings,wails or iloors shall require a 2-hour fire-resistive duct enclosure, and tor others,it shaii be 1 hour. <br /> Type of Const Min.Fire-Resistive Proposed Proposed Material and Construction <br /> Const.of Enclo�ure <br /> I F.R., I� F.R. 2 hour _hr. <br /> II, III, IV,V <br /> 1 hour �hr. ���� � r.� /w �� � <br /> 5. Duct enc�sures shall be separated from ihe duct by at least 3 and nct mae ihan 12 inches.Proposed <br /> in. <br /> 4. Duc�enclosure shall be sealed around lhe duct at the point of penetration and vented to ihe exterior <br /> through a wealher•protected opening. �' �-- <br /> 5. Duct enclosures shall serve only one kitchen exhaust duct. <br /> 6. Tight-fitting access openings shail be provided at each cleanout door. Access enctosure doors shall <br /> have a fire-resistance rating equal to the enclosure. <br /> L Muitiple hoad venting ` <br /> 1. Number of hoods vented by a singie duct system: ro�nded <br /> A single duct system may serve more ihan one hood located in the same story of the bwlding, p <br /> that the interconnecting ducts do not penetrate any fire construction. <br /> 2. A hcod outlet shall serve not more than a 12-foot section of hood. Sheet��� <br />
The URL can be used to link to this page
Your browser does not support the video tag.